X2 Digital inputs/outputs
Assessment
Signal edge, programmable
Input current of each input
2 mA digital input,
20 mA fast digital input
Input propagation delay
Max. 4 ms
Max. 10 µs for fast inputs
Level
Low (0 ... 5 V)
High (12 … 28 V)
Output current of each output
500 mA
Galvanic separation
Optocoupler
Short-circuit resistant
Current limited
Deviating thereof pin No. 2, 3, 9 and 10: NO contact, without a ground reference
Power rating per NO contact:
Max. 30 V, max. 100 mA
Connections on the front side
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
174
7.15
Pin assignment
X2
Pin
No.
BM51XX
Pin
No.
BM51XX
1
N.C.
1)
11 +24 V (supply digital IN/OUT)
+24 V (supply digital IN/OUT)
2)
12 M24V (supply digital IN/OUT)
2
Ready for pulse enabled
13 Digital input 1
3
Ready for pulse enabled
14 Digital input 2
4
Digital output 1
15 Digital input 3
5
Digital output 2
16 Digital input 4
6
Digital output 3
17 Digital input 5
7
Ready-to-operate for PLC
18 Digital input 6
DC link quick discharge
8
N.C.
1)
M24V (supply digital IN/OUT)
2)
19 Digital input 7 error reset
9
Ready for main contactor ON
20 Digital input 8, pulse enable
10 Ready for main contactor ON
1)
Only hardware configuration controller
04
, BM51XX-XXXX-XXXX-XX
04
refer to
2)
Hardware configuration controller from
07
, BM51XX-XXXX-XXXX-XX
07
refer to