Electrical data
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
38
3.4
3.4.3
Electrical data BM3X02-XT, BM3X03-XT, BM3X04-XT, 400 V
a)
with
internal ballast resistor
BM3X02
-X
T
XX-XXXXX-
B
-XXXXX-
b)
without
internal ballast resistor
BM3X02
-X
T
XX-XXXXX-
E
-XXXXX-
Footnotes see
BM3X02
3-phase/3 x 400 V
BM3X03
3-phase/3 x 400 V
BM3X04
3-phase/3 x 400 V
Input rated power output
1)
1.3 kVA
2.3 kVA
4.2 kVA
Input rated current (I
eff
)
1) 2) 3)
1.8 A
3.3 A
6 A
Distortion factor of the input current (THD
I
)
1)
118 %
Input peak current (I
eff
)
1) 2) 3)
6.3 A
11.4 A
15.6 A
DC-link voltage power supply-dependent/rating
540 V
DC
DC-link capacitance (internal)
235 µF
DC-link capacitance (external)
(only devices
BM3X0X
-X
T
XX-XXXXX-
B
)
see DC link connection of additional capacities
from
DC-link discharge time (internal DC-link capacitance)
ca. 450 s
Output voltage
(U
AC
)
1) 4)
0 ... 400 V
Output frequency at 4 kHz
5) 6)
0 ... 450 Hz
Output rated current
(I
AC
)
1)4)7)8)9)
at 2 kHz
5)
1.5 A
2.7 A
5 A
Output rated current (I
AC
)
1)4)7)8)9)
at 4 kHz
5)
1.5 A
2.7 A
5 A
Output rated current
(I
AC
)
1)4)7)8)9)
at 8 kHz
5)
1.1 A
1.9 A
3.5 A
Output rated current (I
AC
)
1)4)7)8)9)
at 16 kHz
5)
0.8 A
1.3 A
2.5 A
Output peak current (I
AC
)
1)4)7)8)9)
at 2 kHz
5)
6 A
11 A
15 A
Output peak current
(I
AC
)
1)4)7)8)9)
at 4 kHz
5)
6 A
11 A
15 A
Output peak current (I
AC
)
1)4)7)8)9)
at 8 kHz
5)
4.2 A
7.7 A
10.5 A
Output peak current
(I
AC
)
1)4)7)8)9)
at 16 kHz
5)
3 A
5.4 A
7.4 A
Max. peak current time
60 s
30 s
Ballast start-up voltage
785 V
Ballast peak power, internal ballast resistor
a)
1200 W for max. 150 ms
Average ballast power, internal ballast resistor
a)
100 W
Permitted ballast current (Î), external ballast resistor
b)
max. 7.0 A
Ballast resistor, external ballast resistor
b)
111
61
Ballast peak power, external ballast resistor
b)
5.5 kW
10 kW
Permitted continuous power of external ballast resistor
b)
2.5 kW
5 kW
Switch on ready-to-operate after
4 s
Max. upload time
0.5 s
Power loss referring to power connection
70 W
Power loss referring to control voltage
max. 30 W
Cooling air requirement
11 m
3
/h
Summary of Contents for b maXX 3000
Page 219: ......