Error handling
Instruction handbook
b maXX
(BM4-F-)AIO-XX (Analog IO module)
Document No.: 5.01045.08
Baumüller Nürnberg GmbH
70
10.3
1st level
1st level errors are only interesting for the access to errors via parameters, to be used
without ProDrive, e. g. at Field bus communication. These errors are not shown in Pro-
Drive/7-segment display.
Bit mapping see description of the parameter P0200 in the parameter manual.
2nd level
3rd level
Order of the error messages see survey (
2nd level error messages are displayed on the 7-segment display in ProDrive.
In the column „Reaction“ the reaction of the system to the error is shown:
m
„pulse stop“ = inhibit pulses
m
„adjustable“ = the error reaction can be set via ProDrive (Window „Drive management“,
toolbar button „Error reaction“).
m
„no reaction“ means, the drive is continuing to work and the red error LED is blinking.
2nd level
error messages
P0204
Error in function or option modules
Error No.
Meaning
Reaction
Troubleshooting
48
Error in function module A
3rd level
error
see
Error in function module A to E
level)
49
Error in function module B
50
Error in function module C
51
Error in function module D
52
Error in function module E