Fuel-Injected Petrol Powered Inverter Generators
9
Engine Starting and Generator Operation
Before starting the engine, ensure that you have followed all procedures described in the
Before
Use Checklist
. • Before starting the generator, disconnect all output sockets so that no load is
immediately placed on the generator as it starts up.
Different models may feature variations in design; for example, some have different engine types, etc. The
following procedures and images are typical to all models, however, the position or appearance of controls
etc may vary. All major engine controls are identified on the machine by way of stickers or other markings.
Once the engine is started, the engine speed will automatically regulate depending on connected load. For
example, under high loads, the engine may run at a higher speed.
Starting and Stopping the Engine
1.
FUEL
– Place the fuel tap (
A
) in the “ON” position and on the fuel filler cap, place the fuel vent (
B
) in the
“ON” position.
2.
IGNITION
– Place the engine ON/OFF switch (
C
) in the “ON” (“
I
”) position.
3.
START
– Slowly pull out the starter cord (
D
) until you feel it engage with the engine, then pull it out
rapidly. Hold the generator handle firmly when pulling the starter cord to prevent the machine toppling
over. The engine should start. Allow the starter cord to rewind slowly – do not let it “snap” back.
If the engine does not start, repeat step 3. If the engine fails to start after several attempts, refer to
Troubleshooting.
Using the Choke
In very cold conditions, if the normal starting procedure is
not working, choke may be required to help start the engine.
To use the choke:
1. Remove the engine access cover (
E
).
2. Rotate the choke lever (
F
) toward the rear of the
machine – this is the “COLD” or “START” position.
3. Start the engine as normal. As the engine warms up,
slowly rotate the choke lever back towards the front of
the machine – this is the “HOT” or “RUN” position.
4. Once the choke is fully in the “HOT” or “RUN” position,
re-install the engine access cover.
NOTE:
If the engine cannot be started, check the engine oil level before any other troubleshooting as the low
oil safety mechanism may be preventing the engine from starting.
Stopping the Engine
1.
OUTPUTS
– Turn OFF any connected devices, then unplug them from the generator.
2.
IGNITION
– Place the engine ON/OFF switch in the “OFF” (“
O
”) position.
3.
FUEL
– Place the fuel tap in the “OFF” position and on the fuel filler cap, place the fuel vent in the “OFF”
position.
A
B
C
D
E
F
Click to Watch:
Inverter Generator Set-Up - Mytopia
Inverter Generator Set-up - Edisons