4.4
Sensor alignment
As standard the sensor is mounted at a right angle (90°) to the reference surface or the object (standard
installation), but it can also be mounted at an angle of up to 30° (angled installation).
To get the most accurate measurements possible in angled installation, the inclination angle of the sensor has
to be taught in, see Section FLEX MOUNT.
The distance from the reference surface or the object must not exceed the "End of measuring range" value on
the measuring axis.
Note
Angle deviations can affect measuring accuracy (see Section Alignment errors).
Tip
To facilitate sensor alignment, LIVE MONITOR monitor can be used as an aid.
LIVE MONITOR continuously outputs the currently measured angle and the
distance from the reference surface.