14
6.2.1 Emergency shutdown at Overtemperature
To prevent damage on the hardware due to high temperatures, the camera is equipped
with an emergency shutdown. The
DeviceTemperatureStatusTransitionSelector
feature
allows you to select different thresholds for temperatures:
NormalToHigh
: freely programmable value
HighToExeeded
: fixed value (camera shutdown if exceeded)
ExeededToNormal
: freely programmable value, temperature for error-free re-ac
tivation of the camera.
In the
DeviceTemperatureStatusTransition
feature, the temperatures for the programma-
ble temperature transitions are set.
The
Event EventDeviceTemperatureStatusChanged
is always generated when
Device-
TemperatureStatus
changes.
If the temperature rises above the value set at
HighToExeeded
, the
DeviceTemperature-
Exceeded
feature is set to
True
, the image recording is stopped, and the LED is set to red.
For further use, the camera must disconnected from the power supply after cooling down
or a device reset should be carried out.
The sufficient cooling is recognizable when the event
EvenDeviceTemperatureStatus-
Changed
(Device Temperature <
ExceededToNormal
) is output.