6.2 Heat Transmission
Caution
Provide adequate dissipation of heat, to ensure that the temperature does
not 50 °C (+122 °F) at temperature measurment point T.
The surface of the camera may be hot during operation and immediately
after use. Be careful when handling the camera and avoid contact over a
longer period.
As there are numerous possibilities for installation, Baumer do not specifiy
a specific method for proper heat dissipation, but suggest the following prin-
ciples:
▪ operate the cameras only in mounted condition
▪ mounting in combination with forced convection may provide proper heat
dissipation
T
T
Measure Point
Maximal Temperature
T
50°C (122°F)
For remote temperature monitoring of the camera a temperature sensor is integrated.
Notice
The temperature sensor is able to deliver values of 0°C (32°F) to +85°C (185°F)
Take care that the temperature of the camera does not exceed the specified case tem-
pe50°C (+122°F).
◄ Figure 2
Temperature measure-
ment points of Baumer
LXC cameras