background image

MB118T1 - 11091890

  Baumer_HOGS151-T1_II_DE-EN (19A1) 

2

 

 General notes 

1

1

 

General notes  

1.1

 

Symbol guide:

 

 

Danger 

 

Warnings of possible danger

 

 

General information for attention 

 

Informations to ensure correct device operation

 

i

 

Information 

 

Recommendation for device handling

1.2

 The 

sine encoder HOGS 151 

is an opto electro nic 

precision measurement device

 which must 

be handled with care by skilled personnel only.

1.3

 

The expected 

service life

 of the device depends on the 

ball bearings

, which are equipped with 

a permanent lubrication.

1.4

 

The 

storage temperature range

 of the device is between -15 °C and +70 °C. 

 

1.5

 

The 

operating temperature range

 of the device is between -20 °C and +85 °C, 

restricted in potentially explosive environments, see section 2, 

measured at the housing.

1.6

 

EU Declaration of Conformity

 meeting to the European Directives.

1.7

 

The device is 

UL approved

 (not applicable for operation in potentially explosive atmospheres).

1.8

 

We grant a 

2-year warranty

 in accordance with the regulations of the ZVEI (Central Association 

of the German Electrical Industry).

1.9

 

Maintenance work

 is not necessary. 

Repair work

 that requires opening the device must be car-

ried out by the 

manufacturer

. Alterations of the device are not permitted. 

1.10

 

In the event of 

queries

 or 

subsequent deliveries

, the data on the device type label must be 

quoted, especially the type designation and the serial number.

1.11

 

Disposal (environmental protection):

 

Do not dispose of electrical and electronic equipment in household waste. The product 

contains valuable raw materials for recycling. Whenever possible, waste electrical and 

electronic equipment should be disposed locally at the authorized collection point. If 

necessary, Baumer gives customers the opportunity to dispose of Baumer products profession-

ally. For further information see www.baumer.com.

Warning!   

Damaging the seal  

  on the device invalidates warranty.

i

Summary of Contents for Hubner Berlin HOGS 151

Page 1: ...MB118T1 11091890 Baumer_HOGS151 T1_II_DE EN 19A1 HOGS 151 Sinus Drehgeber Sine encoder Montage und Betriebsanleitung Mounting and operating instructions...

Page 2: ...ritt 3 10 5 1 4 Schritt 4 10 5 2 Mit Klemmring 11 5 2 1 Schritt 1 11 5 2 2 Schritt 2 11 5 2 3 Schritt 3 12 5 2 4 Schritt 4 12 5 3 Montagehinweis 13 5 4 Option Sperrluftanschluss 13 6 Abmessungen 14 6...

Page 3: ...tep 4 10 5 2 With clamping ring 11 5 2 1 Step 1 11 5 2 2 Step 2 11 5 2 3 Step 3 12 5 2 4 Step 4 12 5 3 Mounting instruction 13 5 4 Option sealing air connection 13 6 Dimensions 14 6 1 With clamping se...

Page 4: ...bschnitt 2 am Geh use gemessen 1 6 EU Konformit tserkl rung gem den europ ischen Richtlinien 1 7 Das Ger t ist zugelassen nach UL gilt nicht f r Einsatz in explosionsgef hrdeten Bereichen 1 8 Wir gew...

Page 5: ...evice is UL approved not applicable for operation in potentially explosive atmospheres 1 8 We grant a 2 year warranty in accordance with the regulations of the ZVEI Central Association of the German E...

Page 6: ...ew hrleisten dass eine m gliche Staubablagerung eine maxi male Schichtdicke von 5 mm nicht berschreitet gem EN 60079 14 2 4 Eine gegebenenfalls an anderen Stellen aufgef hrte UL Listung gilt nicht f r...

Page 7: ...ge from 20 C to 40 C 2 3 The plant operator must ensure that any possible dust deposit does not exceed a thickness of 5 mm in accordance with EN 60079 14 2 4 An UL listing that may be stated elsewhere...

Page 8: ...e vorgegebenen Abst nde und oder Winkel unbedingt einhalten 3 4 Zerst rungsgefahr durch mechanischen Schock Starke Ersch tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemals...

Page 9: ...sential that the specified clearances and or angles are observed 3 4 Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing sys...

Page 10: ...lemmring 1 8 Klemmringschraube M4x16 mm 1 ISO 4762 9 Anschlusskabel siehe Abschnitt 7 3 10 Option Rundsteckverbinder M23 siehe Abschnitt 7 4 1 Je nach Version 1 Housing 2 Through hollow shaft 3 Coupli...

Page 11: ...s 12 Befestigungsschraube M4x10 mm ISO 4762 zur Befestigung des Kupplungsbleches 11 Washer A4 3 ISO 7089 to fix the coupling plate 12 Fixing screw M4x10 mm ISO 4762 to fix the coupling plate 11 12 4 3...

Page 12: ...nn Rundlauffehler verursachen Vibratio nen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft should have as less runout as possible because this can otherwise result in an angle error R...

Page 13: ...N 19A1 10 Montage Mounting 5 Zul Anzugsmoment Max tightening torque Mt 1 Nm Siehe Seite 7 oder 8 See page 7 or 8 5 1 3 Schritt 3 5 1 4 Schritt 4 5 1 3 Step 3 5 1 4 Step 4 2 5 mm 5 4 Zul Anzugsmoment M...

Page 14: ...ler f hren kann Rundlauffehler verursachen Vibratio nen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft should have as less runout as possible because this can otherwise result in an...

Page 15: ...N 19A1 12 Montage Mounting 5 Zul Anzugsmoment Max tightening torque Mt 2 3 Nm Zul Anzugsmoment Max tightening torque Mt 3 4 Nm Siehe Seite 7 oder 8 See page 7 or 8 12 11 3 mm 3 mm 5 4 5 2 3 Schritt 3...

Page 16: ...1 bar ber druck am Sperrluftanschluss betrie ben wird i i To achieve a protection of IP54 it is necessary to mount a maintenance equipment for compressed air see fig 1 so that the device is operating...

Page 17: ...1 L nge und Konfektionierung wie bestellt Connecting cable see section 7 1 Length and conditioning as ordered Option Rundsteckverbinder M23 Option mating connector M23 Option Sperrluftanschluss Option...

Page 18: ...ore end ferrules 7 Elektrischer Anschluss 7 1 Beschreibung der Anschl sse 7 Electrical connection 7 1 Terminal significance UB Betriebsspannung Voltage supply GND 0V Masseanschluss Ground Erdungsansch...

Page 19: ...d Ausg nge Do not connect voltage supply to outputs Danger of damage Please beware of possible voltage drop in long cable leads inputs and outputs 1 9 8 2 10 12 7 3 11 6 4 5 Ansicht X in Rundsteckverb...

Page 20: ...er_HOGS151 T1_II_DE EN 19A1 MB118T1 11091890 8 Demontage Dismounting 8 2 Mit Klemmring Schritt 1 8 3 Schritt 2 8 2 With clamping ring Step 1 8 3 Step 2 Siehe Seite 7 oder 8 See page 7 or 8 12 11 3 mm...

Page 21: ...7 A1 2011 Standard s EN 60079 0 2012 A11 2013 EN 60079 15 2010 EN 60079 31 2014 Norme s EN 50581 2012 Ort und Datum Berlin 15 08 2016 Unterschrift Name Funktion Daniel Kleiner Place and date Signature...

Page 22: ...ussendung EN 61000 6 3 Zulassungen CE UL Zulassung E256710 10 2 Technische Daten mechanisch Baugr e Flansch 168 mm Wellenart 60 70 mm durchgehende Hohlwelle Zul ssige Wellenbelastung 350 N axial 500 N...

Page 23: ...3 Approvals CE UL approval E256710 10 2 Technical data mechanical design Size flange 168 mm Shaft type 60 70 mm through hollow shaft Admitted shaft load 350 N axial 500 N radial Protection DIN EN 6052...

Page 24: ...on is German Technical modifications reserved 11 Accessories Tool kit Order number 11068265 Interpolator HEAG 156 Precision Interpolator Splitter HEAG 158 Precision Sine Multiplier HEAG 159 Precision...

Reviews: