11
Technical data
11.1 Technical data for the components
11.1.1
Sensor ULT 400 XL Sensor
Fig. 1: Dimension sheet (mm)
Data
Value Unit
Length
57 mm
Width
24 mm
Height
65 mm
Data
Value Unit
Operating voltage
24
±
20% V
DC
Current consumption, maximum
150 mA
Measuring principle
Infrared
measure-
ment
—
Scanning frequency
20 kHz
50 µs
Minimum dot size for monitoring
3 mm
Light spot size
12 x 2 mm
Measurement distance to product
62.5
±
12.5 mm
Dimensions ULT 400 XL
Technical data
Technical data
Technical data for the components > Sensor ULT 400 XL Sensor
04.05.2021
ULT 400 XL
48