FlexTop temperature transmitter type 2204 is a compact temperature 
transmitter, designed to be built into the housing of a temperature sen-
sor, like the Baumer CombiTemp.  

The FlexTop temperature transmitter type 2204 is suitable for input 
from Pt500 RTD sensors, potentiometer and resistance input. 

The FlexTop 2204 features a 4 … 20 mA output signal. 

This instrument is built and tested according to the current EU-directives 
and packed in technically safe condition. In order to maintain this condi-
tion and to ensure safe operation, the user must follow the hints and 
warnings given in this instruction. 
During the installation the valid national rules have to be observed. 
Ignoring the warnings may lead to severe personal injury or substantial 
damage to property. 
The product must be operated by trained staff. Correct and safe opera-
tion of this equipment is dependent on proper transport, storage, instal-
lation and operation. 
All electrical wiring must conform to local standards. In order to prevent 
stray electrical radiation, we recommend twisted and shielded input 
cables, as also to keep power supply cables separated from the input 
cables. The connection must be made according to the connecting 
diagrams. 
Before switching on the power supply take care that other equipment is 
not affected. Ensure that the supply voltage and the conditions in the 
environment comply with the specification of the device. 
Before switching off the supply voltage check the possible effects on 
other equipment and the processing system. 

WARNING 

For electrical installation and commissioning of explosion protected 
devices, the data given in the conformity certificate as also the local 
regulations for installation of electrical apparatus within explosion pro-
tected areas must be considered. The intrinsically safe versions can be 
mounted in the explosion hazarded area according to its specification 
only connected to a certified intrinsically safe supply loop with the corre-
sponding electrical values. 

Humidity 

<98 % RH, condensing 

Ambient temperature 

-40 … 85°C   

 

     

Storage temperature 

-55 … 90 °C 

Protection class 

IP00 

Vibrations 

GL, test 2 

 Field of application

 

 Safety instruction

 

 Description

 

 

Environment

 

Operating Instructions: 11109133 02 EN

 

Temperature transmitter 

FlexTop 2204 

Operating instructions

 

 

Configuring with FlexProgrammer 9701

 

The FlexTop 2204 can be configured using the 4...20 mA cable. The 
maximum distance depends on the cable type, resistance and capacity. 
We recommend to use shielded cables. 
To be able to configure the FlexTop 2204 with the FlexProgrammer 
9701 the dedicated software, Flex-program, must be loaded on the PC. 
During the configuration the new data are, by means of the FlexPro-
grammer 9701, transferred from the PC to the FlexTop 2204, where 
they are stored in the internal memory. 

Note: During the first power-up after a configuration the power-on time 
increases to approx. 10 sec. 

 

Dimensions

 

WARNING 

This product contains no replaceable parts. 

 

 

         

In case of malfunction the product must be shipped to Baumer            
for repair 