Baumer_EAM580_360_CANopen_MA_EN_Rev0003.0000h_Index0004.docx
Baumer Electric AG
06.08.2018
19/28
Frauenfeld, Switzerland
9.5
Encoder Diagnostic Sources
The following tables provide a summary of all diagnostic sources supported by the encoder.
Source
Diagnostic Source
Description
Additional Information
Emergency Error Code
Error Code transmitted within the emergency message
Signaling
Object and bit number where the diagnostic source gets visible
Appearance
Describes when the signaling may occur
Reset Behavior
Describes when the signaling of a diagnostic source gets reset
Error Injection Code
Error injection code to simulate a diagnostic source for object 2116-2h
Source
Description
Emergency
Error Code
Appearance
Signaling
Reset
Behavior
Error
Injection
Code
Error reset or no error
An emergency message with
error code 0x0000 will be
transmitted when no more errors
are present
0x0000
at runtime
-
-
0x0000
’0000
Temperature Monitoring
Temperature out of range
0x4200
at runtime
0x1001 Error, Bit 0,3
at runtime
0x0008
’0020
Non-Volatile Data
Manager
Problem with the non-volatile
memory.
0x5100
at startup
0x1001 Error, Bit 0
0x6503 Alarms, Bit 0,1
at reboot
0x0001’0024
at runtime
0x6505 Warning, Bit 3
at reboot
0x0008’0024
Reset Reason Watchdog
SW-reset due to a watchdog timer
issue
0x6100
at runtime
0x6505 Warning, Bit 2
at reboot
0x0008’0025
CAN-Controller Bus
Warning
Communication error (bus
warning)
0x8100
at runtime
0x1001 Error, Bit 4
at runtime
-
CAN-Controller RX Buffer
Overflow
CAN receive buffer overflow
0x8110
at runtime
-
at runtime
-
CAN-Controller Bus
Passive
CAN in error passive mode
0x8120
at runtime
0x1001 Error, Bit 4
at runtime
-
CAN-Controller Bus Off
CAN in bus-off mode
-
at runtime
0x1001 Error, Bit 4
at runtime
-
Lifeguard or Heartbeat
Life guard error or heartbeat error
0x8130
at runtime
-
at runtime
-
Battery Monitoring
Warning
(non-redundant encoder)
Battery low of the Multiturn
system. Encoder should be
replaced
0xFF00
at runtime
0x6505 Warning, Bit 4
at runtime
0x0008’0005
Battery Monitoring
Warning
(redundant encoder)
Battery low of the Multiturn
system. Encoder should be
replaced
0xFF00
at startup
0x6505 Warning, Bit 4
at reboot
0x0004’001C
Battery Monitoring Error
(Battery Empty)
Battery of the Multiturn system is
empty. Absolute position can be
incorrect after restart, encoder
should to be replaced
0xFF01
at startup
0x1001 Error, Bit 0
0x6503 Alarms, Bit 0,15
at reboot
no reset (*
1
0x0001’0004
at runtime
0x6505 Warning, Bit 13
at reboot
no reset (*
1
0x0008’0004
Multiturn Magnetic Field
sequence
(non-redundant encoder)
Incorrect sequence of the
magnetic field (i.e. due to weak or
disturbed magnetic field)
0xFF02
at startup
0x6505 Warning, Bit 12
at reboot
0x0004’0003
at runtime
0x6505 Warning, Bit 12
at reboot
0x0008’0003
Multiturn Magnetic Field
sequence
(redundant encoder)
Incorrect sequence of the
magnetic field (i.e. due to weak or
disturbed magnetic field)
0xFF02
at startup
0x1001 Error, Bit 0
0x6503 Alarms, Bit 0
no reset
0x0001’001A
at runtime
0x6505 Warning, Bit 12
no reset
0x0008’001A
Multiturn Magnetic Field
strength
(redundant encoder)
Magnetic field too low
0xFF03
at startup
0x1001 Error, Bit 0
0x6503 Alarms, Bit 0
no reset
0x0001’001B
at runtime
0x6505 Warning, Bit 12
no reset
0x0008’001B
Multiturn Communication
Monitor
Internal communication error
0xFF04
at startup
0x1001 Error, Bit 0
0x6503 Alarms, Bit 0,12
at reboot
0x0001’0009
at runtime
0x6505 Warning, Bit 13
at reboot
0x0008’0009
Speed Monitoring
Maximum rotation speed
exceeded
0xFF05
at runtime
0x6505 Warning, Bit 0
at reboot
0x0008’0021
Singleturn Magnetic Field
strength
Amplitude of Singleturn sensor
out of range (i.e. due to weak or
disturbed magnetic field)
0xFF06
at runtime
0x6505 Warning, Bit 14
at reboot
0x0008’0022
Singleturn/Multiturn
Supervision
Multiturn- and Singleturn-sensor
out of sync
0xFF07
at runtime
0x6505 Warning, Bit 15
at reboot
0x0008’0023
Multiturn Power On Reset
(redundant encoder)
Power-on-reset during powered-
or unpowered operation (i.e. when
battery is empty). Absolute
position can be incorrect after
restart, encoder should to be
replaced.
0xFF17
at startup
0x1001 Error, Bit 0
0x6503 Alarms, Bit 0,15
no reset
0x0001’0014
at runtime
0x6505 Warning, Bit 13
no reset
0x0008’0014
-
Manufacturer reserved error
codes
0xFF0A…
0xFF16
0xFF17
…
0xFFFF
-
-
-
-
Remark:
In case of any diagnostic source appeared, absolute position may be incorrect.
(
1
: No reset of diagnostic source in case of encoder with redundant design