Baumer_EAx_PROFINET_EN_202011_MNL.docx
64/74
www.baumer.com
11.20
7.4. Supported parameters
7.4.1. PROFIdrive Parameters
P922: Telegram selection
P925: Number of Controller Sign-Of-Life failures which may be tolerated
P964: Drive Unit identification
P965: Profile identification number
P974: Base Mode Parameter Access service identification
P975: DO identification
P979: Sensor format
P980: Number list of defined parameter
7.4.2. Interface Parameters
P61000: NameOfStation (read-only)
P61001: IpOfStation (read-only)
P61002: MacOfStation (read-only)
P61003: DefaultGatewayOfStation (read-only)
P61004: SubnetMaskOfStation (read-only)
7.4.3. Encoder Parameters
P65000: Preset value
P65001: Operating status
7.4.4. Parameter 922: Telegram selection
Read:
Parameter reads the configured telegram type.
Type 81: PROFIdrive telegram 81
Type 82: PROFIdrive telegram 82
Type 83: PROFIdrive telegram 83
Type 860: Standard telegram
with “32 bit I/O + 32 bit speed”
Type 870: Standard telegram
with “32 bit I/O”
Type 100: Manufacturer-specific telegram
with “32 bit I/O + 16 bit speed”
Type 101: Manufacturer-specific telegram
with “32 bit I”
Parameter 922
Type Read only
Data type unsigned int (0x06)
Value range 81-83 (0x0051
– 0x0053), 86-87 (0x0056 – 0x0057), 100 (0x64), 101 (0x65)
Data: 922[0] Telegram type
Value in
parameter 922
Telegram
81
PROFIdrive telegram 81
82
PROFIdrive telegram 82
83
PROFIdrive telegram 83
86
Telegram 860
„32 bit I/O + 32 bit speed”
87
Telegram 870
„32 bit I/O“
100
T
elegram 100 „32 bit I/O + 16 bit speed” (manufacturer-specific)
101
Telegram 101