3.2.3. Push Button for Preset / Reset
Depending on encoder the type the encoder may have a screw cap located where connectors and LEDs are
located as well. After removing the screw cap, the preset / reset push button is visible.
Depending on the current operating state the push button has a different functionality:
In the first 60 seconds after switching on the encoder the encoder performs a
“Factory Reset“.
o
Up to firmware version 1.2.x this only works if the encoder has no Ethernet connection.
o
Since firmware version 1.3.0 this works with and without an Ethernet connection.
With active PROFINET operation the encoder performs a preset.
Note:
After having used the push button the screw cap must be screwed in again and tightened with a torque of
1.5
Nm
.
For functionality details see 0
“ or 4.9 „Restore Factory Defaults“, respectively.