6.1.4
Bus cover connection
•
Release the cap nut of the cable gland.
•
Push the cap nut and seal insert with contact sleeve onto the cable sheath.
•
Strip the cable sheath and cores, shorten the shield film where this exists (see Fig.)
•
Bend over the braided screen by appr. 90°.
•
Push the sealing insert with contact sleeve along as far as the braided shield. Insert the sealing insert
with contact sleeve and cable flush into the cable gland and tighten the cap nut.
•
Terminals with the same designation are internally interconnected.
•
For the power supply, use only cable gland 3. For the bus lines, cable gland 1 or 2 can be optionally
selected. For the bus lines, cable glands 1 or 2 can be freely selected. Observe the admissible cable
cross sections.
•
Insert the cores using the shortest route from the cable gland to the terminal strip. Observe the
admissible core cross-section, in the case of flexible cores use ferrules.
•
Avoid crossing over data lines with the supply voltage line.
•
Close unused cable glands with sealing bolts (supplied).