Manual R600V.DAH5 (EN)
R600V.DAH5_manual_1.5 (EN).docm
Page 11 of 32
Fig 5
Typical Directional Sensitivity of Sensor
Baumer recommends limiting intrusion of objects, into
a rotational cone of approx. 60…70°
from the lens for very weakly reflecting targets. Integration testing must be done to ensure
that the integration with available free space does not have impact on the measurement.
Fig 6
Recommended Free Space for weak targets
For strongly reflecting targets (such as corner cubes and metal plates), the keep out aper-
ture angle is at least +/-3°.
Y
X
X-Axis / H-Plane:
per-
pendicular to centerline /
connector
Y-Axis / E-Plane:
along centerline / con-
nector