Power Supply
Danger!
Use in wet environments requiring IP67 protection
Risk of electric shock. Electric shock can be fatal or cause serious injury.
Use is only permitted under consideration of pollution degree 2 and overvoltage cat-
egory 2.
The M12 connectors must comply with the IEC 61076-2-101 standard.
The dielectric strength and withstand voltage for the plug/socket combination must
be checked according to DIN EN 60664-1:2008-01 for 60 V.
Power V
CC
24 V
±
20 % (Power consumption: max.15.5 W)
Power (IO)
For UL conform installations: 24 V (± 20 %)
For not UL conform installations: 12 V (- 20 %) … 48 V (+ 10 %)
5.1.3
UART0 Interface (≥ Release 3 only)
UART0 Interface
(JST BM06B-SRSS-TB)
5
3
1
4
2
6
1
Power (UART0)
4
UART TxD
2
GND (UART0)
5
not connected
3
UART RxD
6
not connected
Notice
Serial interface voltage level for UART0 TxD and RxD: 0 V (logical 0) ... 3.3 V (5V toler-
ant) (logical 1).
This interface is controllable by UART0 value of
boSerialSelector
and is used to control
optical components.
Class 2 per NEC / Pro-
tection Class III
The device is intended
to be supplied from an
isolated Limited Energy
Source per UL61010-1,
3rd ed cl. 9.4 or Lim-
ited Power Source per
UL60950-1 or Class 2
per NEC.
Notice
Please observe the
instructions and notes
in the technical docu-
mentation of the re-
spective lens!