38
Gap-free assembly
Sealing rings and
Harting Adapter (.FO only)
Do not forget the seals!
Recommended grease
for easier installation:
ELKALUB GLS 867
Tube
Tube Adapter
Camera
Distance Ring
The peak torque while
tightening the
screws is 0.9 Nm.
Use a torque wrench!
Harting Adapter
The peak torque while
tightening the
screws is 0.9 Nm.
Use a torque wrench!
4.7 Cables
For UL conform installations the cables used must meet the following requirements:
▪
shielding for optimum electrical noise immunity
▪
IP67 protection
▪
UL approval
▪
dielectric strength according to the operating voltages used
▪ temperature stability in the specified device temperature range
▪
minimum cross section of cable suitable for max. output current