2.5 CAN Interface (Physical Layer)
The CAN physical layer is according to SAE J1939-15 (reduced physical layer). Some base
parameters are shown in the table below.
Tab 6
CAN Interface
Parameter
Value
Bus Speed
250 kbit / sec (1)
Bus Termination
External termination
Bus Voltage
5V
Wiring
Unshielded twisted pair (UTP)
Cable impedance
120 Ohm (+/- 10%)
(1) may be customized to 500 kbit/sec for customer specific versions.
The bus termination resistor is not included in the device. The bus setup is shown in the figure
below:
Fig 8
CAN connection setup diagram
For further information please refer to the CAN Protocol chapter.
120
120
CAN HI
CAN LO
R600V
Radar Sensor
R600V
Radar Sensor