14
Switching the alarm off
When the pre-set time expires a beep is heard which you can either turn off by touching the (D)
or (E) sensors, or leave it to turn off automatically after 2 minutes.
If you want to switch the timer off prior expiry of pre-set time:
• Touch the timer ON/OFF sensor (F).
• Simultaneously press sensor (E) and (D).
• Simultaneously press (D + E) as many times as necessary to select the alarm, the respective
LED lights on.
• Press (D) until the value »0«. The alarm is deactivated.
SAFETY FUNCTIONS AND ERROR DISPLAY
ERROR CODE
ERROR DESCRIPTION
INSTRUCTION MANUAL
E03 +
continuous
tone, or
Permanent use of keys; Control unit cuts
off after 10 sec. Water or cooking utensils
on the glass above the control unit.
Cleaning of the operational surface. If the problem
persists, Contact authorized center for technical
assistance - specifying the error code.
E21
Control unit cuts off after controlling due to
overheating to avoid damage to
electronics.
Contact authorized center for technical assistance -
specifying the error code.
E22
Defective Key evaluation. Control unit cuts
off after 3.5 - 7.5 sec. Short-circuit or
discontinuation in the range of the key
evaluation.
Contact authorized center for technical assistance -
specifying the error code.
E20
Flash-failure. Microcontroller faulty.
Contact authorized center for technical assistance -
specifying the error code.
E36
NTC value is not within its specification
(value < 200mV or > 4.9V; control unit cuts
off. Short-circuit or cut-off at NTC.
Contact authorized center for technical assistance -
specifying the error code.
E31
Configuration data incorrect. Configuration
of induction necessary.
Contact authorized center for technical assistance -
specifying the error code.
E47
Communication error between TC and
induction.
Contact authorized center for technical assistance -
specifying the error code.
E2
Overheating of the induction coils.
Contact authorized center for technical assistance -
specifying the error code.
EA
Error on the power board. Component
failure.
Contact authorized center for technical assistance -
specifying the error code.
U400
Secondary voltage of the power unit to
high (primary > 300V). Control unit cuts off
after 1 sec releasing a permanent tone.
Control unit is wrongly connected.
Contact authorized center for technical assistance -
specifying the error code.
E5
Error on filter board.
Contact authorized center for technical assistance -
specifying the error code.
E6
Error on power unit.
Contact authorized center for technical assistance -
specifying the error code.
E8
Incorrect fan speed; error on fan left or
right.
Air exhaust blocked, for example by paper.
Contact authorized center for technical assistance -
specifying the error code.
E9
Coil temperature sensor defective.
Contact authorized center for technical assistance -
specifying the error code.
Summary of Contents for BMEH381I
Page 1: ...EN Instructions for use and installation Induction hob LIB30725 R00 090316 BMEH381I BMEH62I...
Page 2: ...2...
Page 17: ...17 1 Fig 1 2 2 3 3 3 4 5 4 1 2 3 4 5...
Page 25: ...25 U 0 1 0 1 2 3 4 5 6 7 8 9...
Page 27: ...27 220 240 V 3 F H05RR F H07RN L N BMEH381I BMEH62I...
Page 29: ...29...
Page 30: ...30 4 5 6 7 9 15 16...
Page 31: ...31...
Page 32: ...32 AR BMEH381I BMEH62I...