5 SERVICE And MAINTENANCE
5.1 Maintenance
Maintenance Chart
General Inspection
Inspect the unit for any buildup of contamination
(dirt, stones, etc.).
Daily.
Hydraulic Hoses
Inspect hydraulic hoses for damage and wear. Daily.
Cutting Teeth
The teeth bolts must be retightened every ten
minutes for the first hour of use on a new drop
saw.
First hour of use.
Cutting Teeth
Check and replace one at a time as necessary.
With daily use expect to replace 4 to 6 teeth per
day. See Replace Cutting Teeth in this section.
Every 4 hours.
17