STEP 3
Remove the cover from the electrical connection box. Using a
suitable terminal screwdriver make secure connections as follows:
Colour Coding:
L - Live = Brown
N - Neutral = Blue
Earth = Green & Yellow
THIS PRODUCT IS MANUFACTURED TO CLASS I
CATEGORY AND MUST HAVE AN EARTH CONNECTION
Close the connection box cover. Restore the mains supply and test
the function of the lights and shaver socket. See operating
instructions below.
L
N
L
N
Live
Earth
Neutral
Mains supply and cabinet cable to correct end
STEP 4
Re-hang the cabinet ensuring correctly located on the hanging
bracket and screw in the lower screws on the bottom to secure
the cabinet and cover with the chrome caps included as shown.
Run a bead of clear silicone sealant on all four sides between
the cabinet carcass and wall surface Allow 24 hours to set before
loading or using the cabinet.
STEP 5
Insert the glass shelves into the shelf supports on the inside profile.The shelf
supports are fixed and aligned during production.However it can be adjusted
to required height and re-alignmert by unscrew the shelf supports.
Glass fragile, please handle with care.