ALLURE LED ILLUMINATED ALUMINIUM CABINETS
WIRING DIAGRAM
IMPORTANT ADVICE & SAFETY
Please read these instructions carefully before starting installation and keep in a safe place for future reference.
Check the contents of the pack carefully before installation. Responsibilty will not be held by Crosswaterfor any de-fit / re-fit costs where faulty product
has been fitted. If any fault is found with materials or workmanship, it must be reported immediately to the manufacturer. Remedial action will be taken,
based on information received, on condition that: 1. Full details are supplied to the manufacturer; 2. The product has not been modified or tampered with;
3. The manufacturer is informed of any damage/shortages prior to installation. 4. The product has not been installed, or attempts made to install. We do
not accept responsibility for any problems that may occur through incorrect installation. ENSURE the room is well heated and ventilated.
Before drilling ensure there are no hidden cables or pipes(water, gas or electrical) behind hanging points. Always wear suitable eye protection
when drilling. Ensure the wall surface is able to take the weight of the complete product.
It is important to install electric fittings in the correct bathroom zone i.e. the zone referred to in the IP rating of the element. Reference should be
made to the latest edition of the IET Wiring Regulations or a qualified electrician member of NICEIC/IET.
ZONE 0 is inside the bath or shower tray itself. Any appliance used in this zone must be rated at least IP67 which is total immersion proof.
ZONE 1 is the area above the bath or shower tray to a height of 2.25m from the floor. In this zone a minimum rating of IPX4 Splash-proof is required and
elements must also be protected by a 30mA residual current device (RCD) to protect the circuit.
The electrical connection to the power supply for these appliances must be in Zones 2/3 of the bathroom in compliance with
BS 7671:2008(2011) - IET Wiring Regulations.
ZONE 2 is an area stretching 0.6m outside the perimeter of the bath and to a height of 2.25m from the floor. In this zone an IP rating of at least IP44 is
required. In addition it is good practice to consider the area around a washbasin, within a 60cm radius of any tap to be considered as zone 2.
Failure to have electrical products installed and certificated by a qualified electrical engineer will invalidate any product guarantee. For full details
reference should be made to the latest copy of the IET wiring regulations and all applicable British Standard and European norm specifications.
This product is IPX4 rated and suitable for installation with zone 2 and 3 as above. The product complies with electrical safety standards BS EN 60598-
1:2008=A11: 2009 and BS EN 60598-2-1:1989
LIVE
EARTH
NEUTRAL
Live supply-Red or brown
Earth supply-Green/yellow
Neutral supply-Black or blue
Live - brown
Earth -Green&yellow
Neutral - blue
This product is Class I rated
and MUST be earthed.
Supply 240v/50hZ maximum