G 120 II V
Page 20
1st Edition, Rev. 0 Chg. 2
3.1.6
Inter-stage Separator
An inter-stage separator is mounted on the compressor block. This separator is designed to remove oil
and water which accumulates due to the cooling of the medium after the compression process. Separation
is achieved by means of centrifugal action provided by a vortex plate (1).
Figure 3-8
Inter-stage Separator
1. Vortex Plate
2. Hollow Screw
3. Center Insert
4. O-ring
5. Knurled Nut
6. Gasket
7. Fitting
8. Safety Valve
^
WARNING
The rapid depressurizing and repressurizing of the inter-stage separator during condensate drain-
ing subjects it to metallurgical stresses. To prevent catastrophic failure with the possibility of
damage, injury or death the inter-stage separator must be replaced after 85,000 load cycles. A
load cycle equals one depressurization- repressurization.
1
2
3
4
5
6
7
8