background image

PLUTONE ’09 v01 

pag. 3 

marzo 2009 

 

5.

 

STAND-BY MODE 

 

 

SET/RESET 

SET

Reset

 

Key which allows access to the menu. To exit the menu 

wait for 5 seconds or press ESC. This key is used also 
to reset warnings 

OK 

Ok

 

Key to confirm the choice made within the menu

 

ESC 

Esc

 

Key to exit the current function or the menu 

UP/DOWN 

 

 

Key to scroll up or down within the menu 

 

6.

 

MEANING OF ICONS 

 

 

FIXED LIGHT: indicates that the boiler is on and its pressure is optimum 

INTERMITTENT LIGHT: indicates that the boiler is on and that the water is 

being heated to obtain steam 

 

Indicates that iron 1 is functioning 

 

Indicates that iron 2 is functioning 

 

Indicates that the pump is pumping water into the boiler

 

 

Indicates  that  the  pump  is  blocked  due  to  the  fact  that  it  has  worked 
without  water  for  a  long  time.  Check  that  water  comes  out  of  the  pipe 

connected  to  the  water  supply.  Turn  off  the  main  switch,  wait  for  5 

seconds and turn the machine on again. If the problem reoccurs, contact 
Authorized Service Centre 

 

Indicates  that  the  maximum  number  of  hours  set  for  the  general 

maintenance of the machine has been exceeded 

 

 

Summary of Contents for PLUTONE 2009

Page 1: ...LLED POWER W 5648 W 5970 POWER OF IRON 1 W 800 W 800 POWER OF IRON 2 W 800 W 800 BOILER POWER W 4000 W 4000 PUMP POWER W 48 Hp 0 5 BOILER CAPACITY 5 L 5 L IRONING ENDURANCE CONTINUOUS CONTINUOUS OPERA...

Page 2: ...protected electrical outlet suitable to PLUTONE power 3 OPENING OF PACKAGE 1 Open the box containing PLUTONE from the upper side marked as ALTO take out the instructions handbook and read it carefull...

Page 3: ...NTERMITTENT LIGHT indicates that the boiler is on and that the water is being heated to obtain steam Indicates that iron 1 is functioning Indicates that iron 2 is functioning Indicates that the pump i...

Page 4: ...4 times fig 3 so that steam comes out this operation must be carried out in order to heat up the hoses which take steam to the iron This prevents also the falling of small drops of water on garments...

Page 5: ...RESET OF WARNINGS Ok FILTER Zeroing of hours SET Reset Ok To exit Esc COVER PROBE Reset is necessary in order to delete the warnings from the display once maintenance has been done Example WARNING PRO...

Page 6: ...nly when the boiler is cold and the plug is disconnected from the mains 3 Never leave hot iron on the ironing board 4 Connect PLUTONE to a suitable and protected outlet 5 After ironing is over switch...

Page 7: ...water fig 3 9 loss of water from PLUTONE base fig 1 10 loss of steam from inner part of PLUTONE 12 MECHANICAL RISKS The following situations are considered dangerous for the operator 1 using PLUTONE f...

Page 8: ...off and are cold fig 2 4 cleaning of the water inlet filter fig 4 and cleaning of the foot valve filter PLUTONE with water tank fig 1 15 CLEANING OF WATER FILTER The cleaning of the filter is to be do...

Page 9: ...ERIODICAL MAINTENANCE TO BE CARRIED OUT EXCLUSIVELY BY AUTHORIZED SERVICE CENTRES QUALIFIED TECHNICIANS OR BY THE MANUFACTURER Compulsory maintenance is signalled by the icon GENERAL MAINTENANCE will...

Page 10: ...osal and recycling of the machine s components assures protection of the natural environment Every product manufactured by BATTISTELLA B G S r l is subject to the following limitations Battistella B G...