background image

Instruction Manual

BatteryMINDer

® 

Plus

Models 12106

*

 / 12106A8V

*

 / 12117

*

 / 12118

*

Charger / Maintainer / Desulfator

*NOT for use with Aviation Type Batteries

READ AND SAVE THESE INSTRUCTIONS

Rev. C-011011 

 

 

P/N VDC121PlusSeriesMNL

VDC Electronics, Inc.

147D Woodbury Rd.

Huntington, NY 11743

www.BatteryMINDers.com

[email protected]

INCLUDES

(1) 2’ Battery Clip Cord Set with 
Quick Connector
(1) 2’ Fused Ring Terminal Cord Set 
with Quick Connector

Summary of Contents for 12106

Page 1: ...h Aviation Type Batteries READ AND SAVE THESE INSTRUCTIONS Rev C 011011 P N VDC121PlusSeriesMNL VDC Electronics Inc 147D Woodbury Rd Huntington NY 11743 www BatteryMINDers com techsupport vdcelectroni...

Page 2: ...PRECAUTIONS 5 CHARGING STATUS 7 SIMPLE Instructions 7 SPECIFICATIONS 7 Charging Stages 8 Indicator Lights 8 Maintenance Button 8 Troubleshooting 8 Voltage Table 9 Charging Maintaining Multiple Batter...

Page 3: ...ld result in a risk of fire and electric shock If an extension cord must be used make sure a That pins on plug of extension cord are the same number size and shape as those of plug on charger b That e...

Page 4: ...h by to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clot...

Page 5: ...e of battery by referring to car owner s manual and make sure it matches output rating of battery charger 13 CHARGER LOCATION a Locate charger as far away from battery as dc cables permit b Never plac...

Page 6: ...or sheet metal body parts Connect to a heavy gage metal part of the frame or engine block g When disconnecting charger turn switches to off disconnect AC cord remove clip from vehicle chassis and the...

Page 7: ...lace the positive red connection on the positive battery terminal Place the negative black connection on the negative battery terminal Plug in the BatteryMINDer On Charging should be red and Battery C...

Page 8: ...Charging light is red anytime the unit is plugged in to 120V AC Power Battery Condition light is GREEN when the unit it is correctly connected to a battery Battery Connection light is FLASHING GREEN...

Page 9: ...el flooded or AGM and condition It is OK to mix deep cycle and starter Charge each battery individually before connecting together Never connect batteries at different states of charge The charged bat...

Page 10: ...allel configuration in order to charge or maintain 4 or batteries in groups of 2 As long as your batteries stay wired together they act as one large battery allowing you to charge and discharge them a...

Page 11: ...ctronics In the event that you believe your product may be defective you MUST speak to a VDC Electronics technician at 1 800 379 5579 x206 ET before proceeding further NOTES Model BatteryMINDer ______...

Page 12: ...st defective material or workmanship and will be repaired or replaced at no charge We make no warranty other than this limited warranty and expressly exclude any implied warranty including any warrant...