Operation
A: R82GB0GA.PMD
B: R82DE0GA.PMD
E: 080403 / T.Wenger
G: 020403 / TCS
Section 6
Page 9
0
6.6
Stopping the program
In Fully Automatic mode the Automatic program
is stopped by using the ”Pstop” function (Stop
program).
Press the F4 function button on the Axis status
page or the F1 function button on the Program
status page to activate the ”Stop program”
function. If the Automatic program uses jumps
to different labels, it is necessary to insert the
Pstop command line.
The Automatic program runs until the last
program line and then stops.
(End of cycle).
The control system is still in Automatic
mode.
Press the TOTMANN button
and
activate the START button to restart the
program sequence at the next program
line.
The ”PStop” function is no longer activated!
Exiting Automatic mode:
Press the MAN button to switch to
Manual mode.
Press the AUTO/SINGLE button to
switch to Single step mode. ( (refer to
5.5.5 Creating token programs).
R8B2_GB118.JPG
R8B2_GB117.JPG