PEGASUS 1100 ELECTRIC HEATED TOWEL RAIL

 

 

INSTALLATION INSTRUCTIONS 

For use with electric supply only. This cannot be used as a dual source towel rail connected to 

the central heating system. 

 

Position: 

This electric towel rail is intended to be installed in a bathroom or shower-room. It is IP54 rated 

and may be wall-mounted in the Zone 2 area (see Fig below), but the electrical connection box 

must be outside the Zone 2 area.  Its position must be such that the thermostat control cannot 

be reached by a person in the bath or shower  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixing to the wall: 

Follow the instructions on pages 3 and 4. 

The 

fixings

 supplied are suitable for use in solid masonry. Use a 10mm bit for the wall plugs 

supplied. The wall must be strong enough to support the weight of the towel rail. For any other 

wall types you will need to source appropriate 

fixings. If fi

tting to a plasterboard wall either utilise 

the noggins, or otherwise strengt

hen do not fix

 through plasterboard alone. 

 

 

Electrical connection: 

The towel rail is supplied complete with its own mains cable. Do not use an extension cable. It is 

a 3-wire product which must be earthed. It should be connected to the household 

fixed 

wiring by 

qualified 

electrician in accordance with the national Wiring Regulations (BS.7671). A switch 

for disconnection from the electricity supply, having a contact separation in all poles that provide 

full disconnection under overvotlage category II

I conditions, must be incorporated in the fixed 

wiring. A switched spur outlet incorporating a 3A fuse may be used, but this must be positioned 

outside  the  Zone  2  area  (i.e.  further  away  from  the  bath  or  shower).  The  national  Wiring 

Regulations also require that each circuit supplying a bathroom must be protected by a 30mA 

RCD in its supply.  

 

 

 

Zone 1

Zone 2

Zone 0

225cm

Zone 1

60cm

1) Side view, bath

2) Top view

3) Side view, shower

Zone 1

Zone 2

225cm

60cm

Zone 1

Zone 0

Zone 2

60cm

60cm

Zone 0