Configuring the Camera
BASLER A102
k
4-13
DRAFT
4.2.4.3 Timer 1
4.2.4.4 Timer 2
Purpose:
To set Timer 1 or to read the current Timer 1 setting. Timer 1 is used when the camera is
operating in ExSync programmable mode or in free-run mode. See Section
for details.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xA6
1
3
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0xA6
0
3
3 Bytes
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xA6
0
3
3 Bytes
Response:
None
Data Format:
Byte 1
Low byte of the Timer 1 setting
Byte 2
Mid byte of the Timer 1 setting
Byte 3
High byte of the Timer 1 setting
Data Range:
Timer settings can range from 15 µs (0x00000F) to
16,777,215 µs (0xFFFFFF).
Purpose:
To set Timer 2 or read the current Timer 2 setting. Timer 2 is used when the camera is
operating in free-run mode. See Section
for details.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xA7
1
3
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0xA7
0
3
3 Bytes
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xA7
0
3
3 Bytes
Response:
None
Data Format:
Byte 1
Low byte of the Timer 2 setting
Byte 2
Mid byte of the Timer 2 setting
Byte 3
High byte of the Timer 2 setting
Data Range:
Timer settings can range from 70 µs (0x000046) to
16,777,215 µs (0xFFFFFF).
Summary of Contents for A102K
Page 4: ......
Page 16: ...Introduction 1 8 BASLER A102k DRAFT...
Page 36: ...Camera Interface 2 20 BASLER A102k DRAFT...
Page 38: ...Operation and Features 3 2 BASLER A102k DRAFT Figure 3 1 A102k Sensor Architecture...
Page 112: ...Configuring the Camera 4 34 BASLER A102k DRAFT...
Page 118: ...Mechanical Considerations 5 6 BASLER A102k DRAFT...
Page 130: ...Feedback iv BASLER A102k DRAFT...