![Basler Vision Technologies Sprint Series User Manual Download Page 186](http://html1.mh-extra.com/html/basler-vision-technologies/sprint-series/sprint-series_user-manual_2707562186.webp)
Configuring the Camera
176
Basler sprint Mono Cameras
Area of Interest Starting Pixel CSR
Register Base Address: 0x1000
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name:
Starting Pixel
Offset
: 0x0001
Size:
2 Bytes
Type
: Read/Write
Description:
Writing an integer to this field sets the starting pixel for the area of interest (AOI) feature.
The area of interest starting pixel can be set to a minimum of 1 and the setting can be increased in
increments of 32 if horizontal binning is not enabled and increments of 16 if horizontal binning is
enabled.
If the value is set to 1, the starting pixel for the AOI will be 1. If the value is set to 33, the starting
pixel for the AOI will be 33. And so on.
The allowed range for this value can vary depending on how the area of interest length parameter
is set. You should check the raw min and raw max fields of this register to determine the allowed
range with the current configuration.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the starting pixel value
Byte 1 = High byte of the starting pixel value
for more information about the AOI feature.
Field Name:
Min
Offset
: 0x0003
Size:
2 Bytes
Type
: Read only
Description:
Minimum allowed integer value for the starting pixel setting. This field is updated to reflect
limitations caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 1 = High byte of the min value
Field Name:
Max
Offset
: 0x0005
Size:
2 Bytes
Type
: Read only
Description:
Maximum allowed integer value for the starting pixel setting. This field is updated to reflect
limitations caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 1 = High byte of the max value
Field Name:
Increment
Offset
: 0x0007
Size:
2 Bytes
Type
: Read only
Description:
An integer value indicating the increment for the starting pixel setting.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the increment
Byte 1 = High byte of the increment
Summary of Contents for Sprint Series
Page 4: ......
Page 10: ...Table of Contents vi Basler sprint Mono Cameras...
Page 42: ...Physical Interface 32 Basler sprint Mono Cameras Fig 14 Camera Frame Grabber Interface...
Page 48: ...Physical Interface 38 Basler sprint Mono Cameras...
Page 76: ...Line Acquisition Modes 66 Basler sprint Mono Cameras...
Page 94: ...Exposure Start and Exposure Time Control 84 Basler sprint Mono Cameras...
Page 230: ...Revision History 220 Basler sprint Mono Cameras...