Configuring the Camera
Basler sprint Mono Cameras
167
Line Acquisition Mode CSR
Register Base Address: 0x3600
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name:
Mode
Offset
: 0x0001
Size:
1 Byte
Type
: Read/Write
Description:
Writing an integer to this field sets the line acquisition mode:
0x00 = Single Line [ Max 70 kHz ]
0x02 = Vertical Binning
0x03 = Time Delayed Line Summing - Line A Delayed
0x04 = Time Delayed Line Summing - Line B Delayed
0x05 = Line Averaging
0x06 = Time Delayed Line Averaging - Line A Delayed
0x07 = Time Delayed Line Averaging - Line B Delayed
0x08 = Dual Line [ Max 140 kHz ] - Line A First
0x09 = Dual Line [ Max 140 kHz ] - Line B First