Configuring the Camera
Basler sprint Mono Cameras
161
Camera Status Inquiry
The camera has been programmed to detect several error conditions. When an error condition is
detected, a flag is set. The camera status inquiry register allows you to read the error flags.
Register Base Address: 0x0C00
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this inquiry register:
0x00 = The register is not available
0x01 = The register is available
Field Name:
Camera Status
Offset
: 0x0001
Size:
4 Bytes
Type
: Read only
Description:
Each bit in this field specifies an error condition (see table below). Bit 0 is the least significant bit.
If a bit is set to 1, the error condition assigned to that bit is present. If the bit is set to 0, the error is
not present.
Bit
Description
0
Reserved
1
The camera is busy performing an internal operation (such as generating shading
values).
2
A reset has occurred.
3
Parameter error. For example, a parameter has been set to a value that is out of range
or not allowed.
4
A user set load has failed.
5
A file operation has failed.
6
A camera power overvoltage condition is present (see Section 6.9.2 on
).
7
A binary read/write command protocol error has been detected. For more information
about the error, read the Binary Command Protocol Status Inquiry Register (see
). This bit is auto-cleared on read.
8 ... 15
Reserved
16
An FPGA not ready error has occurred. For more information about the error, read the
FPGA Status Inquiry register (see
). This bit clears when you read the FPGA
Status Inquiry register.
17
A trigger error has occurred. Either the maximum allowed line rate has been exceeded
or the ExSync signal is missing. For more information about the error, read the FPGA
Status Inquiry register (see
). This bit clears when you read the FPGA Status
inquiry register.
18
Reserved
19
The last shading value generation process failed.
The DSNU shading value generation process can fail if the pixel values in the lines
captured during the generation process are too high. (This process should be
performed in darkness or in very low light conditions.)
The PRNU shading value generation process can fail if the values for the darkest
pixels in the captured lines are less than 1/2 of the values for the highest pixels, This
problem is often caused by extremely non-uniform lighting or by poor quality optics.
This bit will clear when you perform a successful shading value generation process.
20
An overtemperature condition is present (see Section 6.9.1 on
).
21 ... 31
Reserved
Summary of Contents for Sprint Series
Page 4: ......
Page 10: ...Table of Contents vi Basler sprint Mono Cameras...
Page 42: ...Physical Interface 32 Basler sprint Mono Cameras Fig 14 Camera Frame Grabber Interface...
Page 48: ...Physical Interface 38 Basler sprint Mono Cameras...
Page 76: ...Line Acquisition Modes 66 Basler sprint Mono Cameras...
Page 94: ...Exposure Start and Exposure Time Control 84 Basler sprint Mono Cameras...
Page 230: ...Revision History 220 Basler sprint Mono Cameras...