![Basler Vision Technologies Sprint Series User Manual Download Page 139](http://html1.mh-extra.com/html/basler-vision-technologies/sprint-series/sprint-series_user-manual_2707562139.webp)
Features
Basler sprint Mono Cameras
129
6.3.4
Copying the Factory Shading Values into the
User Shading Values File
As explained in Section 6.3 on
, the camera contains a set of factory determined shading
correction values in a file in its non-volatile memory. As explained in Section 6.3.2 on
, you
can also generate a set of "user" shading values and save them to a separate file in the non-volatile
memory.
In some situations, it may be advantageous for you to be able to simply copy the contents of the
factory shading values files into the file for user shading values
You can copy the values from the factory file into the user file with the Camera Configuration Tool
Plus (CCT+) or by using binary read/write commands from within your own application to set the
camera’s bulk data control and status registers (CSRs).
With the CCT+
With the CCT+ (see Section 7.1 on
), you use the File Name Select parameter and the
Copy button in the Shading Files parameters group to copy the data in the factory shading values
file to the user shading values file.
By Setting CSRs
You can copy the data in the factory shading values file to the user shading values file by writing
values to the shading values bulk data CSR.
explains bulk data CSRs and using the bulk data copy process.
explains using read/write commands.
Summary of Contents for Sprint Series
Page 4: ......
Page 10: ...Table of Contents vi Basler sprint Mono Cameras...
Page 42: ...Physical Interface 32 Basler sprint Mono Cameras Fig 14 Camera Frame Grabber Interface...
Page 48: ...Physical Interface 38 Basler sprint Mono Cameras...
Page 76: ...Line Acquisition Modes 66 Basler sprint Mono Cameras...
Page 94: ...Exposure Start and Exposure Time Control 84 Basler sprint Mono Cameras...
Page 230: ...Revision History 220 Basler sprint Mono Cameras...