BASI Instruments BKAP-03 User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IO.KAP-03.02

(ENG) 

 
 
 

BASI INSTRUMENT AB 

 
 

MANUFACTURE OF PRESSURE TRANSMITTERS 

AND CONTROL INSTRUMENTS 

 

 

 
 
 

 

 

USER’S MANUAL 

 

 
 
 
 

FIELD COMMUNICATOR   

 

BKAP-03Ex, BKAP-03 

 
 

Edition A 

 
 
 
 
 
 

 

SWEDEN JANUARY 2013

 

BASI Instrument AB.,   P.O. Box 53, SE-275 06 Vollsj

ö

 

tel. +46 40 88 009 ;   fax +46 40 92 98 77 

 

    

           www.basi.se   e-mail:  [email protected]

Summary of Contents for BKAP-03

Page 1: ...E OF PRESSURE TRANSMITTERS AND CONTROL INSTRUMENTS USER S MANUAL FIELD COMMUNICATOR BKAP 03Ex BKAP 03 Edition A SWEDEN JANUARY 2013 BASI Instrument AB P O Box 53 SE 275 06 Vollsj tel 46 40 88 009 fax...

Page 2: ...urer or to a firm authorized by the manufacturer In order to minimize the risk of malfunction and associated risks to staff the device is not to be installed or used in particularly unfavourable condi...

Page 3: ...STARTING THE COMMUNICATOR 6 7 FINDING THE TRANSMITTER 6 8 UPDATING DATA 7 9 MAIN MENU 7 9 1 INTRODUCTION 7 9 2 COMMUNICATOR S OPTIONS 8 I PRESSURE TRANSMITTERS 8 9 3 INFO 8 9 4 CONFIGURATION 9 9 5 CA...

Page 4: ...s on p 5 The KAP 03 and KAP 03Ex allows also configuration of the other manufacturers transmitters with the HART protocol version 5 or 6 in the field of standard commands GENERIC The communication wit...

Page 5: ...tored in a low temperature it should be warmed up to the room temperature before switching on Available in intrinsic safety version Communicator designated as KAP 03Ex is designed to be used in explos...

Page 6: ...thium ionic battery with nominal capacity of 1 55Ah and voltage 3 6V The battery and its protective elements form a unit covered in polyurethane resin and has the shape of a rectangular cube The charg...

Page 7: ...other than battery set manufactured by BASI The damage analysis and repair may only be performed by the manufacturer or a unit authorized by the manufacturer Attention Fig 1 KAP 03Ex general view see...

Page 8: ...that ranges between 250 and 1100 7 FINDING THE TRANSMITTER During searching for the transmitter the progress bar shows on the Communicator s screen In the searching time addresses from 0 to 15 are in...

Page 9: ...emoving one digit before the cursor whereas a longer pressing it results in removing the whole number Next figures and point may be typed in by pressing appropriate keys of the keyboard After typing i...

Page 10: ...eans that the screen saver shall not be activated 4 Change of calibration code This function allows to change calibration code The original value is 00000000 This code should be entered before pressur...

Page 11: ...er 1 Device address This function enables changing the transmitter address in a range from 0 to 15 Typing in figures the process of typing in figures should be performed according to the description i...

Page 12: ...nce with the above presented format 8 Head number This function enables changing the head number within a range from 0 to 16777215 Typing in characters the process of typing in characters should be pe...

Page 13: ...codes described in the following table CODE DESCRIPTION 1 Error of a measuring circle break dynamic signalling 0 no error 1 error 2 Errors in the ADC transmitter static signalling 0 no error 1 error...

Page 14: ...ure delivered to the transmitter is saved in its memory as the beginning value of the range to be set By typing in a number the beginning value of the range to be set is typed in with the help of the...

Page 15: ...current pressure is displayed on the Communicator s screen in the form of a number and unit If the displayed value is appropriate the zeroing operation should be acknowledged by pressing the F3 key Th...

Page 16: ...of communicator page no 8 a The upper or bottom limit of range The Communicator confirms performance of the calibration by displaying massage CURRENT CALIBRATION SUCCESSFULLY EXECUTED b Setting a cur...

Page 17: ...unction enables setting a comma in any position of the number displayed on the transmitter s LCD screen 6 CONTRAST Contrast adjustment is performed by means of the F2 and F1 keys Pressing the F3 key c...

Page 18: ...the local settings The current status is signalled by displaying one of the following two messages ON OFF The status may be changed by means of the F3 key 10 PROCESS VARIABLES This function is availab...

Page 19: ...LE RANGE 14 END OF ADJUSTABLE RANGE 15 MINIMUM BREADTH OF RANGE 16 TIME CONSTANT 17 SAVING LOCK 18 DEVICE ADDRESS 19 NUMBER OF PREAMBLES 20 SENSOR NUMBER 21 ELECTRONICS VERSIONS 22 PROGRAMME VERSION 2...

Page 20: ...SOR_NOT_CONNECTED 1024 PRIMARY_VARIABLE_NOT_VALID 2048 PRIMARY_VARIABLE_OUT_OF_LIMITS 4096 SECONDARY_VARIABLE_OUT_OF_LIMITS 8192 ANALOG_OUTPUT_SATURATED 16384 OUTPUT_CURRENT_FIXED 32768 HOT_START_OCCU...

Page 21: ...ion enables changing the ID number within a range from 0 to 16777215 Typing in figures the process of typing in figures should be performed according to the description in item 9 1 5 It is possible to...

Page 22: ...4 5 6 7 8 9 A B C D E F Other characters are locked Each character is typed in by one short pressing an appropriate key The typed in characters may not be removed these may only be overwritten In orde...

Page 23: ...d value of the adjustable range Typing in a number the process of typing in should be performed according to the description in item 9 1 3 It is possible to type in 5 figures and the point 4 Time cons...

Page 24: ...Pt10 a 0 003850 l TC TYPE B d Pt50 a 0 003850 m TC TYPE E e Pt98 a 0 003923 n TC TYPE J f Pt100 a 0 003850 o TC TYPE K g Pt100 a 0 003916 p TC TYPE N h Pt500 a 0 003850 r TC TYPE R i PT1000 a 0 003850...

Page 25: ...This function enables choosing a alarm current a LOW b HIGH c USER S possibility of entry of self worth Typing in figures according to the description in item 9 1 3 d LAST VALUE 3 Characteristic proc...

Page 26: ...gures according to the description in item 9 1 5 11 3 CALIBRATION Before calibration ought to be enter calibration code 00000000 Change of calibration code see item 9 2 options of communicator page no...

Page 27: ...ely The breadth of the calibration range may not be smaller than the minimum breadth of set range In order to reach the best possible accuracy it is recommended that the calibration points and the beg...

Page 28: ...NG LCD This function is available only for the transmitters equipped with an LCD display 1 SWITCHING ON OFF LCD This function enables switching on and off the LCD display 2 PROCESS VARIABLES This func...

Page 29: ...e Typing in figures according to the description in item 9 1 3 c End of range This function enables changing the end value of the range which is displayed on the transmitter s LCD screen The current v...

Page 30: ...et KAP 03Ex FIELD COMMUNICATOR Rok produkcji Numer fabryczny KDB 07ATEX122X II 2G Ex ia IIC T4 Gb 1453 Fuse socket Fuse O5x20 EN60127 Charging socket Uo Ui Po Pi Io Ii Ci Li In 0 16A U 250V F adowa na...

Page 31: ...29 IO KAP 03 02 ENG F1 F2 F3 F4 PV RE PF 7 8 9 0 6 5 4 1 2 3 ON OFF ABC DEF GHI JKL MNO PQR STU VWX YZ KAP 03 Ex USE IN THE COVER ONLY COVER KAP03AE Place on wires Fig 2 Cover of KAP 03Ex communicator...

Page 32: ......

Reviews: