Operating elements
3
2
1
4
5
6
1 Foot
2 Mains cable with mains plug (not depicted)
3 Air vent
4 Handle (not depicted)
5 Speed switch
6 Timer knob
Installation
Unbox the product carefully and remove the packaging materials. Lay out the individual
components in an orderly fashion on a clean surface and check them for completeness as per
chapter “Operating elements”, as illustrated above. The foot is composed of two parts. There
are three Phillips screws on the bottom of the tower fan to fasten the foot (1).
• Place the tower fan on a slightly elevated surface (e.g. a table) so the bottom end protrudes
slightly to fasten the foot. If necessary, place a sheet or blanket beneath the product to protect
the surface.
• Remove the three screws from the bottom of the tower fan using a Phillips screwdriver and
put the screws aside (fig. 1). Feed the power cable (2) through the middle of the foot and then
stick the foot together. Make sure the flat side with the rubber feet is down (fig. 2).
Fig. 1
Fig. 2
Fig. 4
Fig. 3
• Then place the assembled foot on the bottom of the tower fan so the openings correspond to
the cam and the screw holes on the product. Make sure the foot is flat against the product.
Use a Phillips screwdriver to screw in the screws hand-tight (fig. 3).
• Guide the power cable to the outside from the middle of the foot. There are recesses and a
cable opening on the bottom of the foot (fig. 4) to this end.
Operation
Place the product with the stand onto a dry, clean, level and stable surface.
Keep sufficient distance to appliances generating heat.
Do not place the product below vases or flowerpots in order to prevent the
product from getting into contact with water.
• The tower fan can be moved using the handle (4). Make sure the tower fan is placed on an
even, stable surface to prevent tipping.
• Make sure the speed switch (5) is in position OFF. Connect the power plug to an appropriate
power outlet.
• Use the speed switch to set the desired fan speed. Air emits from the front of the tower fan via the
air vent (3). The markings 1, 2 and 3 on both sides of the speed switch indicate the fan speed:
1 = low speed, 2 = medium speed, 3 = high speed.
• Oscillation can be set using the speed switch. The arrow marking to the left of the speed
switch indicates oscillating action. Set the speed switch on the left side to the desired speed.
The fan starts rotating to the left and right alternately.
• If no oscillation is desired, set the speed switch on the right side (no arrow marking) to the
desired speed.
• Set the speed switch to OFF to turn off the tower fan.
• Turn the timer knob (6) clockwise to the desired setting from 10 to 120 minutes. The lowest
possible setting is 10 minutes. You can set the time in 10-minute intervals. The fan turns off
automatically after the set time runs down.
• The timer function can also be deactivated manually. To do so, turn the timer knob counter
clockwise to the OFF position.
• The tower fan cannot be turned on with the speed switch (5) when the timer knob is in the
OFF position. Turn the timer knob to the ON position to operate the tower fan without the
timer.
Cleaning and care
• Switch off the product and disconnect the mains plug from the wall socket before cleaning.
• Under no circumstances use aggressive cleanings agents, cleaning alcohol or other chemical
solutions since these can penetrate the housing or impair functionality.
• Use a dry dust cloth to regularly wipe down the tower fan and its components.
•
Never insert fingers, writing utensils or other objects through the air vents to remove filth.
• When not using the product for a longer period of time, cover it and store it at a dry location
protected from direct sunlight.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the
environment.
Technical data
Operating voltage ......................... 220 – 240 V/AC, 50 Hz
Power consumption ...................... 35 W
Protection class ............................ II
Oscillation range ........................... approx. 75 °
Cable length ................................. approx. 1.6 m
Airflow
........................................... approx. 1115 m³/h
Speed settings .............................. 3
Timer function ............................... 120 minutes
Operating/storage conditions ........ -5 to +45 °C, 0 – 65 % RH
Dimensions (Ø x H) ...................... approx. 22 x 79 cm
Weight .......................................... approx. 2.2 kg