Summary of Contents for AV-01KD

Page 1: ...AV 01KD AV 01KD Exported on 08 12 2019...

Page 2: ...n 7 Main 7 Network info 8 Network 9 Custom NTP 9 Panel 9 Apartment settings 9 SIP settings 10 Call settings 11 Device settings 12 Access 12 Common settings 13 Locks management 13 Open lock 14 Addition...

Page 3: ...connection 20 Completness check of the product 20 Electrical connection 20 Mechanical mounting 21 Connection of additional modules 23 Usage of the device 24 Getting the RTSP stream from the camera of...

Page 4: ...4 Device description see page 5 Technical parameters see page 6 Configuration through WEB interface see page 7 Installation and connection see page 20 Usage of the device see page 24...

Page 5: ...call panel with a code set This panel can operate in two modes individual and multi apartment In the individual mode the keypad panel serves as a keypad for opening the lock and using the direct call...

Page 6: ...ndby 2 5 W Power supply 12 volts Body Metallic Color solution titanium gray Dimentions for installation 104 180 60 mm The size of the panel itself 115 190 45 mm Installation Type Flush surface with BR...

Page 7: ...twork segment as the PC from which it is planned to perform the configuration To find the device in the LAN it is required to use Remote search and upgrade tool In the Internet browser in the address...

Page 8: ...version of the framework Launcher A version of the launcher Network info DHCP Current DHCP status IP Current IP address of the device Subnet mask Used subnet mask Gateway Gateway address DNS server D...

Page 9: ...s Mask Subnet mask Gateway The main gateway DNS DNS server address Custom NTP Current device date time Shows the current device s date and time URL Field to enter custom NTP server address Timezone Ch...

Page 10: ...Panel In this mode the call button will work as a concierge call button To work in the individual panel mode with the ability to dial the lock opening code using the keyboard you must select the Pers...

Page 11: ...N server Password Password of SIP number Automatic re registration Re register the device on the SIP server Re registration interval Input field for the time interval in seconds after which the device...

Page 12: ...e The time interval after which the panel automatically ends the outgoing conversation Device settings Video quality Select your preferred video resolution RTP data profile Select your preferred RTP d...

Page 13: ...entering the master code on the panel both locks will open Registering access cards via web interface Enter 0 in the Master card field and click the Apply button Next bring the master card necessary...

Page 14: ...ck begins to open if SIP registration on the panel is lost Open lock Lock 1 Lock 2 Open lock The function of opening the selected lock from the panel WEB interface Additional settings Monitor secure m...

Page 15: ...hrough WEB interface 15 New identifier After clicking on the New identifier button the following interface will appear Identifier number Number of identifier in decimal format Building Unit building n...

Page 16: ...internal monitors when there is no monitor or it is turned off or to any given SIP number Forward settings Mode Mode of the forwarding All at once the call is made to all numbers simultaneously One by...

Page 17: ...t for internal calls sip 1 192 168 1 65 where 1 is the desired number to be displayed by the called party 192 168 1 65 is the IP address of the called SIP client in the case of using a softphone the I...

Page 18: ...splayed during the call System In this section backup and restoration of the panel settings software update language change and software reboot are performed During a call it is possible to switch bet...

Page 19: ...ng the panel configuration file from the PC file system Set default settings Reset all panel settings to factory defaults Backup all settings Save and export configuration files Device language Choosi...

Page 20: ...on of power supply lock and additional modules 1pc Set of end caps for connections 1pc Set screws with a wrench 1pc Electrical connection After verifying whether a device is complete you can switch to...

Page 21: ...el and the lock Mechanical mounting Before mounting the door panel a hole or recess in the wall with dimensions 94 170 60 mm for flush mounting must be provided Overall dimensions of the bracket flush...

Page 22: ...stallation and connection 22 Installation height recomendations The outdoor panel should be installed at a convenient height for you Approximate height of installation is 160 165 cm of the camera leve...

Page 23: ...Installation and connection 23 Connection of additional modules The following modules can be connected to the outdoor panel Module to control two locks SH 42...

Page 24: ...panel To get the RTSP stream from the camera of the call panel to the video surveillance system you need to put in the add line of the camera rtsp admin 123456 192 168 1 16 8554 ch01 where admin is th...