background image

 

 

 

 

 

 

W3110-200U / 200W / 200A - W4110-

200U / 200W / 200A 

 

 

 

 

125633-125633V1-125633V2 - 125634-

125634V1-125634V2 

 

 

 

Summary of Contents for W3110-200U

Page 1: ...W3110 200U 200W 200A W4110 200U 200W 200A 125633 125633V1 125633V2 125634 125634V1 125634V2...

Page 2: ...scher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Technical Support Hotline 49 5258 971 197 www bartscher com Version 1 0 Date of preparation 2021 11 19...

Page 3: ...2 Copyright Protection 7 2 3 Declaration of Conformity 7 3 Transport Packaging and Storage 8 3 1 Delivery Check 8 3 2 Packaging 8 3 3 Storage 8 4 Technical Data 9 4 1 Technical Specifications 9 4 2 Fu...

Page 4: ...structions included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the...

Page 5: ...cal Current Too high a mains voltage or incorrect installation may cause electric shock The appliance may be connected only if data on the rating plate correspond with the mains voltage To avoid short...

Page 6: ...rol spirit alcohol etc High temperature triggers evaporation of these materials and as a result of contact with sources of ignition an explosion may occur In case of fire disconnect the appliance from...

Page 7: ...or prohibited use may cause damage to the appliance The appliance may only be used when its technical condition is flawless and allows for safe operation The appliance may only be used when all conne...

Page 8: ...he following is an intended use Keeping the prepared food warm in suitable GN containers 1 4 Unintended Use An unintended use may lead to personal injuries or property damages caused by hazardous volt...

Page 9: ...ations introduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2...

Page 10: ...It may be used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Par...

Page 11: ...steel plastic Colour elm wenge anthracite Number of basins 1 Basin size GN format 3 x 1 1 GN Max GN container depth in mm 200 Serving height in mm 900 Temperature range min max in C 30 90 Dimensions...

Page 12: ...lm wenge anthracite Number of basins 1 Basin size GN format 4 x 1 1 GN Max GN container depth in mm 200 Serving height in mm 900 Temperature range min max in C 30 90 Dimensions of tray slide shelf W x...

Page 13: ...ON OFF State at delivery assembled for ready to use Features stainless steel basins rounded edges The set includes 4 bars length 528 mm width 30 mm The set does not include GN container We reserve the...

Page 14: ...rated power indicator light green 2 Digital temperature controller 3 LED lighting ON OFF switch 4 LED lighting 5 Sneeze guard bracket 6 Sneeze guard 7 Tray slide shelf 2 pcs 8 GN container basin 9 GN...

Page 15: ...instance plastic bags and EPS If the appliance is covered with a protective film remove it Remove the film slowly so no glue residues are left Remove any glue residues with the use of a suitable solve...

Page 16: ...ips for the User Do not place any objects on the sneeze guard for example do not place a stack of plates To place utensils etc use bottom working surfaces Avoid large amounts of water coming into cont...

Page 17: ...isable the optional internal buzzer and relay Enter key 1 Programming Mode Activation 2 View and confirm new setting values Setting value decrease button 1 Keep pressed together with the Enter button...

Page 18: ...current temperature of the sensor Setting the temperature required value 1 Press the button once for a moment The digital display shows SET The upper point to the left of the temperature gauge is fla...

Page 19: ...rm data are stored the message AL1 min max reached temperature and its duration in minutes appears when temperature 1 was above ALo or AHi next AL2 min max alarm appears AL1 refers to the most recent...

Page 20: ...e display and starts recording the minimum temperature and the alarm duration HACCP function In addition it activates an internal buzzer and an alarm relay if available optional AtP 0 50 AHi 1 AtP 1 5...

Page 21: ...itch The green power indicator light in the ON OFF switch lights up The temperature controller digital display shows OFF 3 Press the temperature controller function button and hold it for 2 seconds to...

Page 22: ...s for Cleaning Before cleaning disconnect the appliance from the power supply Leave the appliance to cool down completely Make sure water does not enter the appliance Do not immerse the appliance in w...

Page 23: ...on Draining Water 4 Clean the GN containers basin thoroughly with a soft cloth and a mild cleaning agent 5 Wipe with a clean cloth 6 Dry the GN containers basin thoroughly afterwards 7 Clean the hygie...

Page 24: ...ctrical appliances must be disposed of and recycled in a correct and environmentally friendly manner You must not dispose of electric appliances with household waste Disconnect the appliance from the...

Reviews: