Installation and operation
14 / 20
289716
EN
• Before connecting, necessarily check the following electric power supply data,
found on the rating plate: voltage, frequency, number of phases and power.
• When establishing a connection, in an easily accessible location, the installer
must connect a main switch, which would interrupt power supply on all poles.
The minimum opening width of contacts must be 3 mm per a pole.
• The power cord must not be routed near heat sources, and room temperature
may not exceed 50°C. The cord must be routed in a metal tube or in a rigid
plastic tube. It must be of, at least, H07 RN-F type.
• The appliance must be connected to a potential equalization system; at the rear
wall, the appliance is equipped with a suitable screw marked with '
' symbol
(Fig. 3)
— it is provided to establish connection. The potential cord must feature
cross-section of at least 10 mm
2
(square mm).
• Do not use the appliance with an external timer or remote control.
5.2
Operation
WARNING!
Risk of burns!
During operation, the housing and basin become very hot and remain
hot for a while after switching the appliance off.
Do not touch the appliance!
To control the appliance, use only designated control elements.
To put and remove food, use only the enclosed accessories.
Fire hazard!
Never place any kitchen utensils, towels, paper, etc., on the roasting
surface
during operation. Do not place plastic nor any other containers on
the roasting surface.
Summary of Contents for ST2ZE