Page 1: ...700FX G180 700FX G280 2839171 2839221...

Page 2: ...cher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Service hotline 49 5258 971 197 www bartscher com 0085DL0223 Version 1 0 Date of preparation 2023 06 07...

Page 3: ...Declaration of Conformity 10 3 Transport Packaging and Storage 11 3 1 Delivery Check 11 3 2 Packaging 11 3 3 Storage 11 4 Technical Data 12 4 1 Technical Specifications 13 4 2 List of Components of t...

Page 4: ...s included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the...

Page 5: ...ce 1 2 Safety instructions Safety of Gas Supplied Appliances Do not use a gas supplied appliance in the event of a malfunction or damage or in the case of a suspected malfunction or damage In such a c...

Page 6: ...catch fire To avoid fire hazard clean the appliance regularly Never leave the appliance unattended especially when cooking with fats or oils as they may cause fire Close the gas shut off valve should...

Page 7: ...In order to avoid or reduce acrylamide content products should always be fried to the point when their colour is golden yellowish and not dim and dark nor brown Burnt left overs and scrubs should be...

Page 8: ...rous situation Warning Danger of slipping or falling User may slip on the floor due to the presence of water or dirt Wear non skid safety shoes when using the device Burn Operator is deliberately touc...

Page 9: ...maintenance work if you touch the internal parts of the machine frame Maintenance work may only be performed by qualified personnel equipped with appropriate personal protective equipment cut resista...

Page 10: ...Standard cleaning X Special cleaning X X Maintenance X X Dismantling X Disposal X X Personal protective equipment provided Personal protective equipment is available or must be used if required Perso...

Page 11: ...ying of adequate food products 1 6 Unintended Use An unintended use may lead to personal injuries or property damages caused by hazardous voltage fire or high temperature The appliance may only be use...

Page 12: ...ntroduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrig...

Page 13: ...e used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularl...

Page 14: ...tion Material Scotch Brite polish Basin with V shaped bowl Basin with large cold zone Grease drain tap Safety thermostat Control knob Temperature control manual May be used as a table top appliance or...

Page 15: ...lume in litres 8 Basin dimensions W x D x H in mm 255 x 520 x 200 Number of baskets 1 Basket dimensions W x D x H in mm 190 x 340 x 110 Basket filling capacity in kg 0 8 Temperature range min max in C...

Page 16: ...Basin dimensions W x D x H in mm 255 x 520 x 200 Number of baskets 2 Basket dimensions W x D x H in mm 190 x 340 x 110 Basket filling capacity in kg 0 8 Temperature range min max in C 100 185 Connect...

Page 17: ...35 PL I3B P G30 G31 37 25 45 BE FR II2E 3 G20 G25 20 25 17 25 30 G30 G31 28 30 37 20 25 35 45 DE II2ELL3B P G20 20 17 25 G25 20 18 25 G30 G31 50 42 5 57 5 ES GB GR IE IT PT SK II2H3 G20 20 17 25 G30 G...

Page 18: ...ppliance categories Gas pressure mbar Connection pressure mbar Rated Min Max DK SE III1a2H3BP G20 20 17 25 G30 G31 28 30 25 35 G110 8 6 15 IT CH II1a2H G20 20 17 25 G110 8 6 15 NL II2EK3B P G20 20 17...

Page 19: ...B GR HR IE IT LT LU LV NO PL PT RO SE SI SK TR G20 G20 G25 20 20 25 UM 145 UP 41 A mm 0 Um DE G25 20 UM 160 UP 41 A mm 0 Um NL G25 3 25 UM 145 UP 41 A mm 0 Um HU G20 25 UM 135 UP 41 A mm 0 Um HU G25 1...

Page 20: ...ef Art No 2839171 74GFRT 2839221 76GFRT PL G30 G31 37 UM 90 UP 25 A mm 0 Um AT CH DE HU G30 G31 50 UM 83 UP 20 A mm 0 Um UM MAX nozzle Um MIN nozzle UP Ignition burner A Open the air ring Pa Connectio...

Page 21: ...6GFRT Rated heat load Qn kW 7 0 14 0 Rated heat load Qn G25 3 25 kW 6 65 13 3 Total gas consumption G20 20 m3 h 0 74 1 48 G25 3 25 m3 h 0 80 1 60 G25 20 m3 h 0 86 1 72 G20 25 m3 h 0 74 1 48 G25 1 25 m...

Page 22: ...ents of the Appliance 2839171 Fig 1 1 Ventilation chimney 2 Bracket for hanging the deep frying basket 3 Basin 4 Housing 5 Piezoelectric igniter 6 Grease drain tap 7 Knob 8 Height adjustable feet 4 pc...

Page 23: ...eet 4 pcs 10 Lid 2 pcs 11 Deep frying basket 2 pcs 12 Sieve for breadcrumb coating 2 pcs 4 3 Functions of the Appliance The deep fat fryer is used to fry suitable food products in hot fat at a suitabl...

Page 24: ...and provides no warranty for damages which may be attributed to non observance of regulations or incorrect installation Observe all provisions of law guidelines and regulations during installation Re...

Page 25: ...the appliance that may restrict the amount of air necessary for burning Before placing the appliance check the dimensions and exact position of gas connections Unpacking Positioning Unpack the applia...

Page 26: ...s surface and horizontal surfaces over the appliance If keeping the minimum clearance is not possible walls should be isolated with non combustible thermo insulation materials e g films made of heat r...

Page 27: ...ed power and length Use only connection tubes with at least diameters equalling the diameter of the appliance s gas connection Gas connection stub is found at the back of the appliance Make sure that...

Page 28: ...nstallation and if needed reset the appliance to the other gas type Tables 1 and 2 in section Technical Specifications provide depending on the country of installation what gas types may be used to po...

Page 29: ...ance 3 Remove the nozzle handle ramp 4 Loosen V bolt Fig 3 5 Remove main burner s nozzle UM Fig 3 and exchange it with a nozzle suitable for the new type of gas part of the delivery Follow information...

Page 30: ...ing different data and indication of the new type of gas Functional Check Before test running install the appliance in a well ventilated room and remove any flammable materials from the vicinity of th...

Page 31: ...rature control knob should be set to lower values WARNING Risk of burns Due to lower flashpoint old oil that had already been used for frying exhibits a tendency for self ignition and favours frothing...

Page 32: ...er can only be used by individuals who have been instructed in the proper use of the appliance and hazards that may arise during the frying process Appliance Preparation 1 Remove the equipment from th...

Page 33: ...Frying Oil or Fat in Cubes Blocks CAUTION Prior to filling with the frying oil or liquid fat in cubes blocks the tank must be clean and dry 1 Make sure the fat drain tap is closed 2 Prior to switchin...

Page 34: ...1 Press the knob 1 and rotate it to position 2 2 Press the knob 1 fully and switch the ignition burner on using the piezoelectric igniter s button 3 Keep the knob 1 pressed for approx 20 seconds and...

Page 35: ...ket NOTE In the case of overfilling the temperature of the frying oil fat in cubes blocks in the basin drops and fried products become very greasy Never overfill the deep fat frying basket with produc...

Page 36: ...ontainer is placed stably NOTE Remove used frying oil fat with care for environment and according to the valid regulations 7 Cleaning and Maintenance 7 1 Safety Instructions for Cleaning Close the gas...

Page 37: ...ipe the surface of the appliance and the control panel only with a slightly damp cloth 7 Wash the frying basket lid and sieve for breadcrumb coating in hot water with a mild cleaning agent Rinse in fr...

Page 38: ...ting panels Remove the retaining screw from the pressure connection Connect the manometer Perform the measurement with an operating appliance Disconnect the manometer and re tighten the retaining scre...

Page 39: ...ogged line or nozzles Contact the service company Spark plug is incorrectly connected or damaged Connect spark plug or replace it Igniter or spark plug line is damaged Contact the service company Dama...

Page 40: ...possible Damaged knob Contact the service company 9 Disposal At the end of the appliance s operational life cycle dispose of the appliance observing national and local regulations To this end we reco...