- 35 -
Connecting the device
DANGER! Electrical hazard!
Improper connection of the device to a power source may lead to injury from
electric shock!
Before installing, compare the local network’s parameters with the rating
plate on the device. Only connect the device to a power source when it is
compliant with all parameters.
The device must only be connected to a properly installed single socket with
protective contact.
Never remove the power cable by pulling the cable itself; always grab the plug
housing.
•
Attention! If the device is tilted further than 30°, wait a mi nimum of 4 hours before
connecting it to a power source. Failure to wait may lead to damage to the compressor.
•
After switching the device off (for cleaning, repair, relocation, etc.) it must be switched
on only after at least 15 minutes.
•
The socket and circuit must be secured to a minimum of 16A. Only connect the
device to a wall socket, do not use power strips or splitters.
•
Locate the device so that the plug is easily accessible in case it is necessary to
quickly disconnect the device from its power source.
Changing the door closing direction
•
When required, the refrigerator door may be switched from right to left side.
Note: In case of key-locked door it is not possible to change the closing direction.
•
It is recommended to use help of another person during changing the door closing
direction. Required tools: wrench for bolts 8 and 10, Phillips screwdriver.
CAUTION!
Before changing the door closing direction switch the device off by removing
the plug from the socket.
CAUTION!
During changing the door closing direction do not place the refrigerator in the
horizontal position.