Bartscher 300301 Instructions For Installation, Use And Maintenance Manual Download Page 4

 

rev. 1 – 12/10/2018

 

 

4/12

 

 

INSTALLATION 

Installation, assembly and troubleshooting must only be performed by skilled personnel strictly in accordance 
with the following instructions : 

Remove the machine from the packing and throw away the protection pieces. 

Remove the protection film from the equipment and the strap from the cover. 

Keep a minimum distance of 10 cm. all around the machine in order to allow adequate 
cooling of the pump during running (the machine could have difficulties to reach the desired 
vacuum). 

Set the machine perfectly straight by adjusting the supporting feet until the correct position 
has been reached. A wrong alignment of the machine could affect the performance during 
running. 

For the installation of the machine an omnipolar switch must be mounted between the power 
network and the equipment and it must have a minimum contact distance of at least 3mm 
per pole. Allow easy access to the switch. 

The rating plate is on the rear of the machine. From the plate can be checked if the 
equipment is set to run with the available line voltage. Check that the available power 
voltage matches the one printed on the rating plate. 

During running of the machine the voltage must be /- 10% of the correct rating. 

Earthing the equipment is mandatory in order to avoid damaging the electronic board. 

It is strictly mandatory to comply with the fire regulations! 

   

 
 
 
 
 

 

DIRECTIONS 

ATTENTION : To avoid spilling oil from the pump which could damage the equipment never turn the machine 
upside down or incline it. 
THE EQUIPMENT MUST BE PLACED IN A WORKING ENVIRONMENT WITH AN AMBIENT 
TEMPERATURE NOT LESS THAN 12°C. 
 
 
 
 
 

 

LEGAL REGULATIONS, TECHNICAL RULES AND DIRECTIVES 

During the installation the following rules and regulations must to be observed : 

Legal regulations in force (to be defined Country by Country) 

Accident protection requirements and laws in force (to be defined Country by Country). 

 
 
 
 
 
 

 

ELECTRICAL CONNECTION 

See enclosed wiring diagrams. 
Check the power supply and voltage with the rating on the plate. The machine is supplied with cable and 
plug. 
 
 
 

 

REPLACING OF THE CONNECTING CABLE 

In case of cable replacement check the electrical scheme. 
The  replaced  cable  must not be less than type H05 RN-F in quality and shall have a minimum wire section 
of 3x1,5 mm

2

 . 

During connection carefully make sure that the earth wire is longer than the others. In case of an unexpected 
strong pull on the cable or in case the cable clamp breaks the earth wire must be the last to disconnect from 
power. 
The machine can only be started after having checked that all these safety precautions have been carefully 
observed. 

Summary of Contents for 300301

Page 1: ...Vacuum packaging machines Mod 300301 INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE ...

Page 2: ...rev 1 12 10 2018 2 12 ...

Page 3: ...obtaining the desired vacuum degree by the almost complete air extraction from inside the packaging In this way the product maintains its characteristics of colour taste flavour etc for a longer time The rating plate is positioned at the rear of the machine and contains all necessary data for the installation type consumption voltage etc INSTRUCTION FOR INSTALLATION DRAWING OF THE EQUIPMENT TECHNI...

Page 4: ...n 10 of the correct rating Earthing the equipment is mandatory in order to avoid damaging the electronic board It is strictly mandatory to comply with the fire regulations DIRECTIONS ATTENTION To avoid spilling oil from the pump which could damage the equipment never turn the machine upside down or incline it THE EQUIPMENT MUST BE PLACED IN A WORKING ENVIRONMENT WITH AN AMBIENT TEMPERATURE NOT LES...

Page 5: ...ture has to be increased or decreased Air intake phase Air re enters the chamber bringing again the atmospheric pressure conditions in the chamber A valve allows the air intake into the chamber OPERATOR INFORMATION Train the operator on the equipment with the help of the instruction book Always hand over the instruction book to the operator Suggest the operator contracts for the maintenance servic...

Page 6: ...e the equipment see fig 3 The product C must be perfectly in line with the sealing bar A this is achieved by regulating the trenchers D these trenchers allow in fact the lining up of the product and the filling up of the chamber for a quicker vacuum effect The bag B must be carefully placed on the sealing bar A in order to avoid folds which could affect the sealing The bag must never be bent at th...

Page 7: ... to vacuum pack the product with a lower vacuum degree and seal the bag it is necessary to push the button STOP C and wait for a few seconds until the cover lifts up NOTICE Do not touch the wires of the sealing bar right after the sealing process they are still hot Do not proceed to seal if the sealing bar is damaged and immediately replace it Do not run the equipment if the chamber is wet or damp...

Page 8: ...m with a temperature higher than 12 C The bar does not seal Sealing time not long enough Reset the sealing time Electrical terminals of the sealing bar are not connected Connect the electrical terminals of the sealing bar The machine cycle stops at 97 and does not run further Humidity of the air this happens rarely Put the equipment in a dry environment Reduce the vacuum down to 97 Proceed with ma...

Page 9: ...ng the sealing bar install it with the flat wire turned towards the inside of the chamber For cleaning of the Plexiglass lid use a wet chamois type cloth or similar IN ORDER NOT TO DAMAGE THE LID NEVER USE OTHER DETERGENT PRODUCTS Before any long stand by of the machine proceed carefully with the cleaning as described above REPLACEMENT OF THE SEALING BAR TEFLON Disconnect the equipment from the po...

Page 10: ...DIVIDUAL PROTECTIVE MEASURES The purpose of the use of personal protective equipment and clothing is to protect a certain part of the body from specific risks in connection with operational work In principle it should only be used if primary measures to eliminate the risks are no longer adequate to ensure the complete avoidance of harmful substances and therefore the health and safety of the worke...

Page 11: ...SAFETY LABELING the device provides various safety indications WARNING Get rid of the machine in a proper way following the national disposal rules Always protect the machine from the interventation of not authorized persons ...

Page 12: ...ates this trouble because the product is protected in a heat resistant bag and therefore maintains its organolectic properties VACUUM COOKING In Italy as well as in France and in Germany the vacuum packaging of previously cooked food is becoming more and more normal practice In this way the taste and the nutrient characteristics of the food can me preserved satisfying every requirements also durin...

Reviews: