background image

Pag. 29/55 

 
 
 
 
 
 
 
 
 
 
 
 

SERIE 900 MASTER 

GAS BRAISING PAN 

MOTORIZED GAS BRAISING PAN 

ELECTRIC BRAISING PAN 

MOTORIZED ELECTRIC BRAISING PAN 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLATION, USE 
AND MAINTENANCE 

 

 
 
 

  296.600        296.670       296.680
  295.6001      295.6701     295.6801    

Summary of Contents for 295.6001

Page 1: ... 29 55 SERIE 900 MASTER GAS BRAISING PAN MOTORIZED GAS BRAISING PAN ELECTRIC BRAISING PAN MOTORIZED ELECTRIC BRAISING PAN INSTALLATION USE AND MAINTENANCE 296 600 296 670 296 680 295 6001 295 6701 295 6801 ...

Page 2: ... MISURE D INGOMBRO G C G C E E 2956001 2956701 Fig Abb 1 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse E C G C G E 2956801 Fig Abb 2 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse ...

Page 3: ...Pag 3 55 C C E E 296600 296670 Fig Abb 3 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse E C E C 296680 Fig Abb 4 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse ...

Page 4: ...GR GB Nr II2H3 p mbar 28 37 20 ES IE CH TIPO TYPE A II2E3P p mbar 37 20 PL MOD II2ELL3B P p mbar 50 50 20 20 DE ART II2H3B P p mbar 50 50 20 AT CH CZ SK N II2H3B P p mbar 28 30 28 30 20 FI LT BG kW B II2H3B P p mbar 28 30 28 30 20 NO SK RO Σ Σ Σ ΣQn m h C II2H3B P p mbar 28 30 28 30 20 EE SI HR TR kg h D I3B P p mbar 50 50 HU II2L3B P p mbar 30 30 25 NL kW E V F III1ab2H3B P p mbar 28 30 28 30 20 ...

Page 5: ...ngement du gicleur du brûleur veilleuse Substituting the pilot burner nozzle Austausch der Zündbrennerdüse Fig Abb 13 Istruzioni uso versione a gas Instructions d utilisation gaz versions Instruction for use gas version Bedienungsanleitungen gasgerät Fig Abb 14 Istruzioni uso versione elettrico Instructions d utilisation versions électriques Instruction for use electric version Bedienungsanleitung...

Page 6: ...otorized Bedienungsanleitungen motorische kippung Fig Abb 17 18 Sostituzione della valvola in sicurezza Changement du vanne de sécurité Substituting the safety valve Austausch der sicherheitsventil Fig Abb 19 20 21 Sostituzione delle resistenze Changement du résistances Substituting the heating element Austausch der panzerwiderstande ...

Page 7: ...0x900 1250x620x170 132 28 A1 2 208 0 423 56 UNI ISO 7 1 R 0 2555 230 1 50 3x1 296670 Electric Braising Pan 1 manual unit 900x900x900 800x620x170 86 5 9 230 3 400 3N 50 4x4 5x2 5 296600 Electric Braising Pan 1 motorized unit 900x900x900 800x620x170 86 5 9 25 230 3 400 3N 50 4x4 5x2 5 296680 Electric Braising Pan 1 5 motorized units 1350x900x900 1250x620x170 132 13 25 230 3 400 3N 50 4x4 5x2 5 Table...

Page 8: ...ity kW Reduced Capacity kW Diam Main Injector 1 100 mm By pass Diameter 1 100 mm Pilot Injectors N Air Regulation x mm BRAISING PAN BURNER 1 UNIT Liquid Gas LPG G30 G31 19 00 110 x 4 30 Close BRAISING PAN BURNER 1 5 UNIT Liquid Gas LPG G30 G31 28 00 110 x 6 30 Close Table 5 BURNER FEATURES LV CAT I2H Gas Type Normal Capacity kW Reduced Capacity kW Diam Main Injector 1 100 mm By pass Diameter 1 100...

Page 9: ...0 x 6 51 Close Table 7 BURNER FEATURES SE DK FI CAT II2H3B P III1ab2H3B P III1a2H3B P Gas Type Normal Capacity kW Reduced Capacity kW Diam Main Injector 1 100 mm By pass Diameter 1 100 mm Pilot Injectors N Air Regulation x mm BRAISING PAN BURNER 1 UNIT Liquid Gas LPG G30 G31 19 00 110 x 4 30 Close Natural Methane Gas G20 19 00 190 x 4 51 Close Town Gas G110 19 00 450 x 4 100 Close Town Gas G120 19...

Page 10: ... Gas Type Normal Capacity kW Reduced Capacity kW Diam Main Injector 1 100 mm By pass Diameter 1 100 mm Pilot Injectors N Air Regulation x mm BRAISING PAN BURNER 1 UNIT Liquid Gas LPG G30 G31 19 00 95 x 4 30 Close BRAISING PAN BURNER 1 5 UNIT Liquid Gas LPG G30 G31 28 00 95 x 6 30 Close Table 10 BURNER FEATURES PL CAT II2E3P Gas Type Normal Capacity kW Reduced Capacity kW Diam Main Injector 1 100 m...

Page 11: ...s booklet For the installer The functioning of the appliance must be explained and shown to the user After having ensured that everything is clear the instruction booklet must be handed over The user must be informed that any building modification or restructuring that may in any way modify the air supply necessary for combustion makes it necessary to carry out another check of the functionality o...

Page 12: ...to be adjusted The external coating is made of Chrome Nickel 18 10 stainless steel Each pan is provided with a thermostat that allows temperature control in a range from 90 C to 300 C inclusive safety is ensured by means of a safety manually controlled thermostat The pan is made entirely of stainless steel with a manual or motorized lifting system depending on the type Heating is by means of elect...

Page 13: ...ir exchange necessary for the well being of the operators in accordance with the norms in force Approximately a total of 35 m3 h per kW of gas output installed INSTALLATION Preliminary operations Remove the appliance from the packaging ascertaining that it is intact and if in doubt do not use it but call in professionally qualified personnel After having verified that the appliance is in good cond...

Page 14: ...an the other conductors and that the connecting cable has a wire bunch adequate for the power absorbed by the appliance and is at least type H05 RN F As in international provisions before installing the appliance a multiple pole device must be installed with a contact opening of at least 3 mm that must not interrupt the YELLOW GREEN earth wire The device must be installed near the appliance it mus...

Page 15: ... shown in the table of burner features for the lowest heat capacity of the type of gas foreseen for use with the appliance This value can be found in the norm tables or can be provided by the local gas Supply Company E Capacity Calorific Value The reading must be done when the appliance is already in function Checking the pilot burner Check the flame of the pilot burner which must be neither too s...

Page 16: ...crew 9 that blocks the primary air regulation open the clamp wide 10 and unscrew the nozzle 11 with a spanner and replace it with an appropriate nozzle for the type of gas to be used as shown in tables 2 10 Put back the nozzle tightening it well and then adjust the primary air as indicated in the following paragraph When all this has been done put back the previously removed parts Regulating the p...

Page 17: ...eating position the two pilot lights go on the green one stays on permanently to show the presence of voltage while the orange one goes out as soon as the pan reaches the required temperature To switch off turn the knob to the 0 position Manual Tilting Fig 15 pag 5 Tilting of the manual series is obtained using the crank 1 at the front of the appliance The pan rises by turning the crank clockwise ...

Page 18: ...e sure that the appliance is disconnected from the electric mains and that the gas cut off valve is closed The following maintenance operations must be carried out at least once a year by specialised personnel It is advisable to have a maintenance contract Check for correct functioning of all control and safety devices Check for correct ignition of burners and proper functioning at minimum Check t...

Page 19: ...ement box 2 and the support of the heating element to be replaced 3 by loosening the screws that hold it 4 Remove the heating element 5 after disconnecting it If replacement is difficult it can be made easier if the control panel is removed 6 and the front panel 7 as shown in figure 8 and then turn the pan towards the front after having removed the pin 8 and the split pin 9 Take great care in doin...

Reviews: