BAR H
Elektronik GmbH
®
5/6
9021-0021-A
09.05.2019
A
Page:
Document:
Date:
Revision:
Parameter Programmer
PG-65
Art. No. 0017-0065
MANUAL
© 2017 BARTH Elektronik GmbH | Im Depot 1-3 | D-49838 Lengerich | www.barth-elektronik.de
® BARTH is a registered trademark. All rights reserved.
9021-0021-A
3
Appendix
3.1
Specifications
3.1.1 General
Hardware design
BARTH
®
Parameter Programmer
with resistive touch display
integrated in a rugged aluminium
diecast housing.
Programming options
PG-65: factory preprogrammed
Mini-PLC: Open Source,
C-Programming, using the
powerful KEIL
®
µVision
®
Software,
free license
Interfaces
USB (charging only)
CAN 2.0A/B
IrDA/SIR
3.1.2 Power supply
Operating voltage
7 to 32 VDC
Current consumption
100 mA @ 12 VDC
55 mA @ 24 VDC
45 mA @ 32 VDC
Fusing
1 to 5 A max. (external)
mandatory for voltage reversal
protection
Voltage reversal protection
yes
(combined with external fuse)
ESD/TVS protection
yes, integrated
Heat dissipation air
(at full load)
normally < 1.5W
Internal battery
Li-Io 3.7V/600mAh
Operation Time
> 4 h (auto power off: 5 min)
Charging time
< 6 h via USB power 5VDC
3.1.3 Display
Technology
TFT (Thin-Film Transistor)
Liquid Crystal Display Module
Size
2.4” Diagonal
Resolution
240 x 320 Pixels / 262K colors
Touch
4-wire Resistive Touch Panel
Backlight
LED white
3.1.4 Interfaces
CAN
CAN 2.0A/B:
11/29 bit ID, base frame format
Baud rates:
50, 100, 125, 250, 500 kbit, 1Mbit
Internal termination resistor: 1k
(for direct connection to one
Mini-PLC), meets or exceeds the
requirements of applications ISO
11898-2, loss of ground
protection from –32 V to +32 V,
thermal shutdown protection
USB
1.0/2.0/3.0 (charging only)
IrDA (infrared)
SIR (9.6 kbit/s to 115.2 kbit/s)
IrPHY (for factory use only)
3.1.5 Security features
Security Features
System and independent
watchdog
Fail safe oscillator
Power on/down reset
Supply voltage supervisor
3.1.6 Program and data memory
Memory
5Mb Flash, 196k RAM
3.1.7 Timebase (oscillator)
Primary Oscillator
Crystal quartz MEMS unit
(precise ‚micro-electro-mecha-
nical system‘)
Nominal Frequency
16.000 MHz
Frequency tolerance
±50 × 10
-6
Frequency aging
±5 × 10
-6
/ year max.
3.1.8 Electrical connection
Electrical Connection
plugable spring terminal
connectors 0.25 to 1.5 mm²
Manufacturer: Phoenix Contact
Series: COMBICON
Type: FMC1,5/4-ST-3,5(-BK)
3.1.9 Electromagnetic compatibility (EMC)
Electrostatic discharge
(ESD) at supply terminals
20 kV air discharge
30 kV contact discharge
(IEC/EN 61 000-4-2, level 3)
Electromagnetic fields
Field strength 10 V/m
(IEC/EN 61000-4-3)
CAN bus terminals
(CANH, CANL to GND)
IEC 61000-4-2:
Unpowered Contact Discharge
±15000 V
IEC 61000-4-2:
Powered Contact Discharge
±8000 V
3.1.10 Environmental conditions
Operation temperature
-10 to +55 °C
(IEC 60068-2-1/2)
Storage temperature
-20 to +55 °C
(IEC 60068-2-1/2)
Relative humidity
5 to 80% non-condensing
(IEC 60068-2-30)
Air pressure (in operation)
500 to 1500 hPa
Shock resistance
min. 50 m/s²
(IEC 60068-2-27)
Vibration resistance
min. 10 m/s² @ 10..100 Hz
(IEC 60068-2-6)
Degree of protection
IP 20 (EN 50178, IEC 60529)
Free fall (packaged)
1000 mm
(IEC 60068-2-32)