Parameter Programmer
PG-65
Art. No. 0017-0065
MANUAL
© 2017 BARTH Elektronik GmbH | Im Depot 1-3 | D-49838 Lengerich | www.barth-elektronik.de
® BARTH is a registered trademark. All rights reserved.
9021-0021-A
2.4
Editing parameter(s)
To edit parameter(s) read out via CAN or IrDA from a Mini-
PLC, please follow the steps below:
Power ON the PG-65 and press this
button to read the parameter(s) from
the Mini-PLC´s internal EEPROM.
Wait until OK appears, then press OK.
Edit the parameter(s) by pressing this
button.
Increasing the yellow-colored
parameter or value.
Decreasing the yellow-colored
parameter or value.
Escape from edit mode or menu.
Confirm data or edit a parameter or
value. Yellow-colored values are ready
to be changed.
Store parameter(s) into the Mini-PLC´s
internal EEPROM.
Wait until OK appears, then press OK.
Switch OFF the PG-65 or resume
operation.
2.5
USB charging
The PG-65 Parameter programmer integrates a 3.7V Li-Io
battery for mobile operation for several hours.
To charge the internal battery, please connect the PG-65
using the micro-USB cable to an USB port or 5VDC power
adaptor/power bank.
2.6
Operation with KEIL
®
µVision
®
To operate the PG-65 with a BARTH
®
Open Source Mini-
PLC (e.g. STG-800 or STG-810) please refer to the product
related manual. Any Open Source Mini-PLC featuring CAN
or IrDA can be easily interfaced to the PG-65.
2.2
CAN and power supply connection
The PG-65 is able to be powered by the internal 3.7V Li-Io
battery, USB (5VDC) or an external power supply from 7 to
32 VDC. In case the PG-65 is external powered, take care to
meet the following rules:
Turn off the power supply before perfor-
ming any wiring operations!
False electrical connection, voltage
reversal or disregarding the electrical
specifications may cause irreversible
damage of the PG-65!
Use an external 1A fuse to protect the
PG-65 against voltage reversal.
The voltage at CANH or CANL must not
exceed -32 or +32 VDC referred to ground
(GND). Higher voltages may cause irre-
versible damage of the Mini-PLC!
The graphic below shows the PG-65 connector layout:
Power supply and CAN connector
1
+VDD
positive supply (+7 to 32 VDC)
2
GND
ground terminal (GND)
3
CANH
CAN high terminal
4
CANL
CAN low terminal
All terminals are carried out as plugable spring terminal
connectors for a wire gauge of 0.25 to 1.5mm².
There is a 1k termination resistor integrated in the PG-65 to
ensure proper operation in direct connection to a BARTH
®
Mini-PLC without using an additional termination resistor in
your CAN network.
Please also refer to the appendix for detailed electrical
specification of the CAN interface.
2.3
IrDA connection
In case the Mini-PLC should be connected via IrDA interface,
please ensure a visible distance of 500mm at maximum
between both devices.
The PG-65´s IrDA interface is placed at the fronside of the
programmer. The Mini-PLC´s IrDA interface (small window)
is placed near to model name lettering (e.g. ‚STG-810‘).
Simply use the PG-65 like an IR remote control pointing at
the Mini-PLC´s IrDA interface.