General 

This  operating  manual  contains  all  necessary  instructions  for  the  installation,  commissioning,  operation  and 
maintenance of the mp6-XOEM. The manual is intended to help you achieving optimal results in a short time and 
shall also assist avoiding possible sources of errors. The operating manual of the other controllers, micropumps and 
the accessories are available separately. 

The  products  have  been  designed  with  state-of-the-art  technology  and  in  accordance  with  all  relevant  safety 
regulations. However, a risk of damage to the units, other property, the operator and/or other persons cannot be 
fully excluded.  

Always ensure that specialized and trained personnel will comply with the following general instructions. 

Therefore, please keep this manual and hand out copies as required. 

Bartels  Mikrotechnik  GmbH  rejects  any  responsibility  for  damages  to  persons  or  property  resulting  from  non-
compliance with the instructions in this manual. In this case all warranties shall be void. 

Declaration of conformity 

Bartels  Mikrotechnik  GmbH  declares  that  the  products  are  compliant  to  the  RoHS  directive  2011/65/EU.  The 
controller complies with the requirements of EMV 2014/30/EU and CE markings have been affixed to the devices. 
Additionally, the controllers are also compliant to the EU Low Voltage Directive 2014/35/EU. 

Description of functions 

The micropumps have been developed for the transport of gases or liquids. The controllers have been developed for 
operating  the  micropumps.  Bartels  Mikrotechnik  can  assume  no  liability  for  damages  resulting  from  the  pump 
media. This applies especially for hazardous fluids. 

The pumps must be operated with Bartels Mikrotechnik electronics. Bartels Mikrotechnik GmbH cannot guarantee 
the  proper  work  of  the  units  with  customer  specific  electronics.  If  other  controllers  than  the  ones  from  Bartels 
Mikrotechnik are used, Bartels Mikrotechnik disclaims any warranty. 

Moreover,  please  note  that  components  of  the  controller  and  pump  are  operating  with  high-voltage. 

Therefore, 

persons wearing pacemakers are recommended to avoid the operating system. 

Bartels Mikrotechnik assumes no liability for abnormal handling, improper or negligent use of the micropump and 
the  controller that is not conform to the  specified purpose  of the  system. This applies especially for micropump 
controllers,  components  and  systems  of  other  manufacturers,  which  have  not  been  certified  by  Bartels 
Mikrotechnik.

 

We guarantee that the micropumps comply with the actual state of scientific and technical knowledge  hence the 
operational risks are limited to a minimum.  

Do not open the housing of the micropump and the controllers

.

 In those cases, Bartels Mikrotechnik cannot issue a 

guaranty anymore. Please keep this manual safe and give a copy to all users. 

Summary of Contents for microComponents mp6-XOEM

Page 1: ...1 Rev 1 2 04 2020 Operating Manual for Controller mp6 XOEM...

Page 2: ...this operating manual 4 The mp6 XOEM controller 5 Technical specifications mp6 XOEM 5 Electrical Characteristics 6 Pin description 7 Connecting the micropump with the mp6 XOEM 8 Examples of circuiting...

Page 3: ...ant to the EU Low Voltage Directive 2014 35 EU Description of functions The micropumps have been developed for the transport of gases or liquids The controllers have been developed for operating the m...

Page 4: ...ditions including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning...

Page 5: ...w additional components or a microcontroller In order to locate Pin 1 please refer to the following figure The pin is marked with a colored spot or triangular marking on the corner of the PCB Technica...

Page 6: ...LITUDE 0 5 1 3 VDC min voltage at pump Vpump AMPLITUDE 0 5 VDC 10 Vpp max voltage at pump 1 Vpump AMPLITUDE 1 25 VDC 250 260 270 Vpp Frequency output F VDD 5 V Default 200 Hz Digital Low Signal 0 V Di...

Page 7: ...ut 0 Address inputs allow up to four connections on one common bus Connect A0 to GND or VDD 8 P1 Piezo actuator 1 positive electrode see page 9 9 P1 Piezo actuator 1 negative electrode see page 9 10 P...

Page 8: ...d with the mp6 XOEM via a FCC connector More information concerning this connector and the pin layout of the micropump can be found in manual of the micropump mp6 series DANGER The output of the mp6 X...

Page 9: ...amplitude to the micropump will be defined by external components The amplitude can be varied in the range from 0 Vpp to 250 Vpp Using a voltage divider it is possible to set the amplitude with only...

Page 10: ...citor This can only be done my supplying a clock signal to the CLK pin witch is shown in the next chapter Operation with variable settings via microcontroller Using a microcontroller to operate the mi...

Page 11: ...f the mp6 QuadOEM on our download page To activate the I C Interface the onboard processor has to be deactivated by tying the reset pin to Ground Select a desired slave address connecting pins A0 and...