70 of 246
Remote Station Operational Status – “Statcall”
“Statcall” allows the operational status parameters of any Barrett transceiver fitted
with Selcall to be accessed. This status is sent from the remote transceiver as a
Selcall with the status information embedded within the Selcall structure.
Information retrieved for remote diagnosis of transceiver performance includes:-
Selcall ID
Software version
Option level fitted and transceiver model
Receive state battery voltage
Last transmit state battery voltage
Signal strength indication of received status request Selcall.
Forward power output level
VSWR of antenna
Requesting Another Stations Status
select the channel you want to send the Status request call on.
(“Beacon Call” can be used to select the best channel)
listen for traffic on that channel, if no traffic is heard then continue.
Then press the
key
select “Status Request” with the scroll keys
then press the
key
enter the identification of the station you want to request the
operational status from (see “
Entering station IDs and using the
address and telephone books”)
then press the
key