barox Kommunikation
9
The factory default settings of the CLI interface are as follows :
Bit rate:
115,200
Data bits
8
Parity:
None
Stop bits:
1
Flow control: None
If the serial interface is used to connect up to the switch, the user needs to log on using the user
name and password.
The following command can be used to show the IP address:
RY-LGSP23-26#
show ip interface brief
➔
Important: This change now needs to be permanently saved.
To do this, access the switch by entering the new IP address in the web browser and then click
on the diskette symbol at the top right-hand corner.
3.4
Gateway Configuration
If a new IP address is allocated to the switch, it is also mandatory to modify the gateway address
accordingly.
To change the gateway address, the respective line f irst needs to be deleted and then re-created
using the right address. The network address must be set to “0.0.0.0” and the mask length to “0”.
Then all that needs to be done is to rewrite the gateway address using one that corresponds to
the network.
3.5
Time Configuration
The system time used by barox Kommunikation switches can either be configured manually or
via an NTP server. The whole purpose of defining the time is to use it in the log file. If an error
message is generated, a date stamp is added to the respective entr y in the log file so that the
downtime and/or the time when the error occurred is accurately recorded which helps to localise
the possible cause.
3.5.1. Local Settings
In the “Configuration/System/Time” menu, select “Use Local Settings” as “Clock Source”. The
date and time are then manually entered in the specified format in the field next to
“System Date”
and then confirmed using the “Apply” button.
➔
If the switch is restarted, the time is deleted and needs to be re-configured as the switch
does not have its own backup battery.