Fuel
Inspection of Fuel Quantity
With the machine on a level surface, observe
the fuel level in the monitor to check the fuel
level.
1
2
FUEL LEVEL
OIL PRES
guc5f6-009
Inspection of Fuel Quantity_001
1
Monitor
2
Fuel level
Fuel Supply
Warning
Do not supply additional fuel after the fuel
level indicates 100%.
If you supply too much fuel, it might overflow
from the fuel cap when you travel or work on a
slope.
Warning
Keep fire away while refueling.
Do not smoke.
Important
Use ultra-low sulfur diesel fuel (sulfur-free
diesel fuel).
Important
In case of lack of fuel, DPF regeneration can
not be performed.
If the monitor displays the warning message
"FUEL LEVEL LOW", immediately stop
operation, and then supply fuel (diesel).
The fuel tank capacity is approximately 51.0
dm
3
(51.0 L).
Note:
The factory default low fuel level is 10%.The
level can be changed optionally.
1
2
FUEL LEVEL
OIL PRES
guc5f6-009
Fuel Supply_001
1
Monitor
2
Fuel level
Air Bleeding of Fuel System
Important
The air-bleed plug should always be in the
closed position except during the air bleeding
operation.
Using the machine with the air-bleed plug in
the open position may cause the engine to
stall.
This machine has a function of automatic air
bleeding.
However, depending on the mechanical
structure, it may not bleed air completely.
If the automatic air bleeding does not work
well, follow the steps below to perform manual
air bleeding.
Caution
Do not perform air bleeding when the engine
is hot since a fire might occur.
Set the ignition key to the "ON" position.
Turn the air-bleed plug on the fuel filter
several times to loosen it.
When a bubble no longer arises, screw the
air-bleed plug to the original position.
Set the ignition key to the "OFF" position.
1.
2.
3.
4.
Handling Instructions
LM551B
Handling Instructions
Page 4-13
Daily Check List
Summary of Contents for LM551B
Page 6: ...LM551B Introduction ...
Page 8: ...LM551B Contents ...
Page 14: ...LM551B Safety Page 1 6 Safe Operating Practices ...
Page 30: ...LM551B Product Overview Page 3 14 Safety Signs and Instruction Signs ...
Page 32: ...Before Long Term Storage Page 4 84 LM551B Handling Instructions Page 4 2 ...
Page 168: ...LM551B Maintenance Page 5 54 Maintenance Work ...
Page 169: ......
Page 170: ......
Page 171: ......