Engine Start/Stop Circuit
There are five switches related to engine operation, each of which operates a relay in coordination
with each switch.
These are configured so that the following switches control multiple circuits.
Reel rotation switch
Reel forward/reverse switch
Seat switch
Proximity switch/Parking brake
Proximity switch/Neutral
Operating outline of electrical circuits during engine operation
When engine operation conditions are satisfied, the Relay 2/Stop solenoid operates and the fuel
cut solenoid is activated along with it.
While the fuel cut solenoid is activated, fuel continues to be supplied to the engine to continue
operation of the engine.
If there is a malfunction such as the starter operating but the engine does not start, or the engine
starts but then stops, inspect and adjust the engine start/stop circuit
1.
2.
3.
4.
5.
・
Electrical System
LM551
Electrical System
Page 5-15
Electrical Circuit Configuration