Forward/reverse pedal proximity switch NC
Inspection of Control Output
Caution
Do not short-circuit the battery terminals.
Follow the steps below to connect the
battery and a tester to the connector
terminal of the forward/reverse pedal
proximity switch NC.
Connect the battery (+) to the connector
terminal (+), and the battery (-) to the
connector terminal (-).
Connect the tester (+) to the connector
terminal Vout (+), and the tester (-) to the
connector terminal (-).
Normal operation is that there is continuity
between connector terminals 2 and 3 when
the plastic magnet is getting away to the
proximity switch and there is no continuity
between connector terminals 2 and 3 when
the plastic magnetic is getting close from
the proximity switch.
-
+
-
+
1
2
3
6it54e-003
Inspection of Control Output_001
1.
[1]
[2]
2.
1
Connector terminal (+)
2
Connector terminal Vout (+)
3
Connector terminal (-)
Electrical system
FS900
Electrical system
Page 5-11
Electrical components
Summary of Contents for FS900
Page 1: ...Riding Sweeper Service Manual Serial No FS900 10001 Ver 1 0...
Page 4: ...FS900 Contents...
Page 10: ...FS900 Safety Page 1 6 Safety Signs and Instruction Signs...
Page 11: ...Waste Disposal Page 2 2 About the Waste disposal Page 2 2 Disposal FS900 Disposal Page 2 1...
Page 28: ...FS900 Maintenance standards and maintenance Page 3 16 Greasing...
Page 74: ...FS900 Hydraulic system Page 4 46 Inspection and repair of each section...
Page 98: ...FS900 Electrical system Page 5 24 General inspection and repair...
Page 118: ...FS900 Main body Page 6 20 Inspection and repair of each section...