Service Manual
495B SE (S)
63
Last Updated - 9/28/2016
3. If any of these tests show zero voltage, repair or replace wiring.
4. Check voltage again until correct reading appears.
CHECKING ALTERNATOR OUTPUT
1. Disconnect negative battery cable.
2. Remove wire from "BAT" connector on alternator and fasten it to one connector of an ammeter. Fasten other
connector of ammeter to "BAT" connector of alternator.
3. Connect battery cable again.
4. Remove hot wire from electric solenoid on fuel injection pump and turn engine with starter for approximately
30 seconds to cause a partial discharge of battery.
5. Install hot wire on electrical solenoid and start engine and run at full engine RPM.
6. The ammeter reading must be within 10 percent of rated amperage marked on alternator case.
7. If reading is correct, alternator is good. If reading is more or less than 10 percent of rated amperage, check
regulator.
CHECKING THE REGULATOR
1. Use steps 1 through 5 of "Checking Alternator Output".
2. Put a small screwdriver in test hole. See Figure 3.
3. If the ammeter reading is not within 10 percent of rated amperage (marked on alternator case), regulator may be
damaged. Check diode trio, rectifier, stator, or rotor.
Damage to alternator can occur if:
- battery connections are not connected properly.
- wires from alternator are grounded.
- engine is operated with battery cables disconnected.
-
cables are connected when using a fast charger or when welding on the loader. (Remove both cables
from the battery.)
- extra battery cables (booster cables) are connected wrong.
ELECTRICAL SYSTEM MAINTENANCE CONTINUED...
Summary of Contents for 495B - SE
Page 3: ...Introduction...
Page 15: ...Maintenance...
Page 18: ...Service Manual Last Updated 9 28 2016 495B SE S 18 SERVICE SCHEDULE...
Page 19: ...Service Manual 495B SE S 19 Last Updated 9 28 2016 SERVICE SCHEDULE CONTINUED...
Page 20: ...Service Manual Last Updated 9 28 2016 495B SE S 20 SERVICE SCHEDULE CONTINUED...
Page 21: ...Service Manual 495B SE S 21 Last Updated 9 28 2016 SERVICE SCHEDULE CONTINUED...
Page 22: ...Service Manual Last Updated 9 28 2016 495B SE S 22 SERVICE SCHEDULE CONTINUED...
Page 28: ...Hydraulic...
Page 29: ...Service Manual 495B SE S 29 Last Updated 9 28 2016 HYDRAULIC DRAWING 603 01594...
Page 30: ...Service Manual Last Updated 9 28 2016 495B SE S 30 HYDRAULIC SERVO DRAWING 603 01593...
Page 31: ...Service Manual 495B SE S 31 Last Updated 9 28 2016 HYDRAULIC SCHEMATIC 607 00185...
Page 32: ...Service Manual Last Updated 9 28 2016 495B SE S 32 HYDRAULIC DRAWING TANDEM 603 01574...
Page 33: ...Service Manual 495B SE S 33 Last Updated 9 28 2016 HYDRAULIC SERVO TANDEM 603 01573...
Page 34: ...Service Manual Last Updated 9 28 2016 495B SE S 34 HYDRAULIC SCHEMATIC TANDEM 607 00184...
Page 56: ...Electrical...
Page 71: ...Service Manual 495B SE S 71 Last Updated 9 28 2016 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 72: ...Service Manual Last Updated 9 28 2016 495B SE S 72 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 73: ...Service Manual 495B SE S 73 Last Updated 9 28 2016 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 74: ...Service Manual Last Updated 9 28 2016 495B SE S 74 AIR CONDITIONER MAINTENANCE CONTINUED...
Page 78: ...Maintenance...
Page 88: ...Structural...
Page 93: ...Trouble Shooting...